Product Description
The LRS Series is a compact and cost-effective industrial switching power supply designed to convert 220V AC input into stable 24V or 12V DC output. It meets diverse power requirements for automation equipment, LED lighting, control systems, and industrial machinery. Built with high-quality components, it ensures high efficiency up to 90%, low ripple noise, and full protection against overload, overvoltage, and short circuit. Its lightweight metal housing and screw terminal design allow for easy installation and long-term durability in demanding environments.
Functional Features
FULL POWER MULTIPLE PROTECTION STABLE PERFORMANCE
PURE COPPER TRANSFORMER IMPORTED CHIP DIRECT DEAL
Full Power
Brings a Brand-New Experience
Strong Power, up to 500W
Durable Output
More Stable Operation
Powerful Heat Dissipation
Rapid CoolingTwo distinct heat dissipation modes are available: fan cooling and honeycomb structure cooling, effectively protecting internal components.
Dust Cover Design
Safety Design
Junction box protective cover reduces dust ingress, prevents accidental contact,and enhances operational safety.
Product Views
Stable Performance
Full power, stable performance, high-frequency transformer
Multiple Intelligent Protection.
Built-in intelligent protection system, effectively safeguards against safety hazards.
Wiring Diagram
Easy Wiring, bringing you closer to a better understanding of our products.
①Neutral Input
②Line Input
③Earth Wire
④Output Negative
⑤Output Positive
⑥Adjustable Potentiometer
1.
Overvoltage Protection
Overload Protection
Short Circuit Protection
Overtemperature Protection
2.
High-quality electrolytic capacitors
High-frequency copper-core transformer
3.
Application
With industrial-grade quality and high-quality components, the LRS series ultra-thin switching power supply has a wide range of applications. It can stably adapt to monitoring equipment, providing continuous and reliable power support for security monitoring systems to ensure 24-hour normal operation of the equipment. At the same time, it is suitable for medical equipment and automatic control equipment, meeting the strict requirements of such precision equipment for power supply stability. In addition, it can also be applied to urban lighting projects, providing safe and stable power supply for various lighting fixtures, and can also adapt to various industrial control equipment, helping industrial production operate efficiently. With its stable performance and wide adaptability, this power supply has become the preferred power supply equipment in many fields.
Product parameters
LRS-35
MODEL | LRS-35-5 | LRS-35-12 | LRS-35-15 | LRS-35-24 | LRS-35-36 | LRS-35-48 | ||
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | 48V | |
RATED CURRENT | 7A | 3A | 2.4A | 1.5A | 1A | 0.8A | ||
CURRENT RANGE | 0 ~ 7A | 0 ~ 3A | 0 ~ 2.4A | 0 ~ 1.5A | 0 ~ 1A | 0 ~ 0.8A | ||
RATED POWER | 35W | 36W | 36W | 36W | 36W | 38.4W | ||
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | ||
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
LOAD REGULATION Note.5 | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
SETUP, RISE TIME | 1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 373VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFICIENCY (Typ.) | 82% | 86% | 86% | 88% | 88% | 89% | ||
AC CURRENT (Typ.) | 0.7A/115VAC 0.42A/230VAC | |||||||
INRUSH CURRENT (Typ.) | COLD START 45A/230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||
PROTECTION | OVER LOAD | 110 ~ 150% rated output power | ||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 5.75 ~ 6.9V | 13.8 ~ 16.2V | 18.75 ~ 21.75V | 28.8 ~ 33.6V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | ||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
OVER VOLTAGE CATEGORY | Ⅲ; According to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters | |||||||
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16 ,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004,AS/NZS 60950. 1(by CB),KC K60950-1(for LRS-35-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 10) approved | |||||||
SAFETY & EMC(Note9) | WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B , BS EN/EN55014 , BS EN/EN61000-3-2 ,-3 , GB17625 . 1 ,GB/T 9254 . 1 , BSMI CNS15936 , EAC TP TC 020 ,KC KN32 ,KN35(for LRS-35-12/24 only) | |||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8, 11, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN55035, heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-35-12/24 only) | |||||||
OTHERS | MTBF | 3201.5K hrs min. Telcordia SR-332 (Bellcore) ; 655.5Khrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 99*82*30mm (L*W*H) | |||||||
PACKING | 0.21Kg ; 60pcs/14Kg/0.93CUFT | |||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 7. 5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. 8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft). 9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMI testing of component power supplies.” 10. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. | |||||||
LRS-50
MODEL | LRS-50-3.3 | LRS-50-5 | LRS-50-12 | LRS-50-15 | LRS-50-24 | LRS-50-36 | LRS-50-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 10A | 10A | 4.2A | 3.4A | 2.2A | 1.45A | 1.1A | |
CURRENT RANGE | 0 ~ 10A | 0 ~ 10A | 0 ~ 4.2A | 0 ~ 3.4A | 0 ~ 2.2A | 0 ~ 1.45A | 0 ~ 1.1A | |
RATED POWER | 33W | 50W | 50.4W | 51W | 52.8W | 52.2W | 52.8W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 2.97 ~ 3.6V | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 373VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFICIENCY (Typ.) | 80% | 83% | 86% | 88% | 88% | 89% | 90% | |
AC CURRENT (Typ.) | 0.95A/115VAC 0.56A/230VAC | |||||||
INRUSH CURRENT (Typ.) | COLD START 45A/230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||
PROTECTION | OVER LOAD | 110 ~ 150% rated output power | ||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 3.8 ~ 4.45V | 5.9~ 7.3V | 13.8 ~ 17.2V | 18.75 ~ 25.75V | 28.8 ~ 36.6V | 41.4 ~ 51.6V | 55.2 ~ 67.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
OVER VOLTAGE CATEGORY | Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters | |||||||
SAFETY & EMC (Note 9) |
SAFETY STANDARDS | UL62368-1 , TUV BS EN/EN62368-1 , BS EN/EN60335-1 , BS EN/EN61558-1/-2-16 ,GB 4943 . 1 , BSMI CNS15598-1 , EAC TP TC 004 , AS/NZS 60950 . 1(by CB) ,KC K60950-1(for LRS-50-12/24 only) , BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 10) approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB17625 . 1,GB/T 9254 . 1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only) | |||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only) | |||||||
OTHERS | MTBF | 3149.8K hrs min. Telcordia SR-332 (Bellcore) ; 561.6Khrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 99*82*30mm (L*W*H) | |||||||
PACKING | 0.21Kg; 60pcs/14Kg/0.93CUFT | |||||||
NOTE | 1. AII parameters NOT speciaIIy mentioned are measured at 230vAC input, rated Ioad and 25℃ of ambient temperature. 2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor. 3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation. 4. Line reguIation is measured from Iow Iine to high Iine at rated Ioad. 5. Load reguIation is measured from 0% to 100% rated Ioad. 6. Length of set up time is measured at coId first start. Turning ON/OFF the power suppIy Very quickIy may Iead to increase of the set up time. 7. 3.3v,5v when the Ioad factor 0~50%, the switching power Iess is reduced by burst operation, which wiII cause rippIe and rippIe noise to go beyond the specifications. 8. The ambient temperature derating of 5℃/1000m is needed for operating aItitude greater than 2000m(6500ft). 9. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by mounting the unit on a 360mm*360mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directiVes. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.” 10. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. | |||||||
LRS-75
MODEL | LRS-75-5 | LRS-75-12 | LRS-75-15 | LRS-75-24 | LRS-75-36 | LRS-75-48 | ||
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | 48V | |
RATED CURRENT | 14A | 6A | 5A | 3.2A | 2.1A | 1.6A | ||
CURRENT RANGE | 0 ~ 14A | 0 ~ 6A | 0 ~ 5A | 0 ~ 3.2A | 0 ~ 2.1A | 0 ~ 1.6A | ||
RATED POWER | 70W | 72W | 75W | 76.8W | 75.6W | 76.8W | ||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | ||
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | ||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
LOAD REGULATION Note.5 | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
SETUP, RISE TIME | 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 60ms/230VAC 12ms/115VAC at full load | |||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 373VDC | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFICIENCY (Typ.) | 86.5% | 89% | 89% | 90% | 91.5% | 91.5% | ||
AC CURRENT (Typ.) | 1.4A/115VAC 0.85A/230VAC | |||||||
INRUSH CURRENT (Typ.) | COLD START 65A/230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||
PROTECTION | OVER LOAD | 110 ~ 150% rated output power | ||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18.75 ~ 21.75V | 28.8 ~ 33.6V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | ||
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
OVER VOLTAGE CATEGORY | Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178,BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters | |||||||
SAFETY& EMC (Note 8) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004,AS/NZS 62368.1(by CB),KC62368-1, BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9) approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB17625 . 1,GB/T 9254 . 1, BSMI CNS15936, EAC TP TC 020,KC KSC 9832, KSC 9835 | |||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8, 11, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN55035, heavy industry level,EAC TP TC 020,KC KSC 9832, KSC 9835 | |||||||
OTHERS | MTBF | 3334.3K hrs min. Telcordia SR-332 (Bellcore) ; 667.2Khrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 99*97*30mm (L*W*H) | |||||||
PACKING | 0.23Kg ; 45pcs/ 11.5Kg/ 0.77CUFT | |||||||
NOTE | 1. AII parameters NOT speciaIIy mentioned are measured at 230VAC input, rated Ioad and 25℃ of ambient temperature. 2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor. 3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation. 4. Line reguIation is measured from Iow Iine to high Iine at rated Ioad. 5. Load reguIation is measured from 0% to 100% rated Ioad. 6. Length of set up time is measured at coId first start. Turning ON/OFF the power suppIy Very quickIy may Iead to increase of the set up time. 7. The ambient temperature derating of 5℃/1000m is needed for operating aItitude greater than 2000m(6500ft). 8. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by mounting the unit on a 360mm*360mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directiVes. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.” 9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. | |||||||
LRS-100
MODEL | LRS-100-3.3 | LRS-100-5 | LRS-100-12 | LRS-100-15 | LRS-100-24 | LRS-100-36 | LRS-100-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 20A | 18A | 8.5A | 7A | 4.5A | 2.8A | 2.3A | |
CURRENT RANGE | 0 ~ 20A | 0 ~ 18A | 0 ~ 8.5A | 0 ~ 7A | 0 ~ 4.5A | 0 ~ 2.8A | 0 ~ 2.3A | |
RATED POWER | 66W | 90W | 102W | 105W | 108W | 100.8W | 110.4W | |
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 2.97 ~ 3.6V | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load | |||||||
HOLD UP TIME (Typ.) | 55ms/230VAC 10ms/115VAC at full load | |||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC 120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFICIENCY (Typ.) | 84.5% | 86% | 88% | 88.5% | 90% | 90.5% | 91% | |
AC CURRENT (Typ.) | 1.9A/115VAC 1.2A/230VAC | |||||||
INRUSH CURRENT (Typ.) | COLD START 50A/230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||
PROTECTION | OVER LOAD | 110 ~ 150% rated output power | ||||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 3.8 ~ 4.45V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18.75 ~ 21.75V | 28.8 ~ 33.6V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | ||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||
OVER VOLTAGE CATEGORY | Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters | |||||||
SAFETY & EMC (Note 8) |
SAFETY STANDARDS | UL 62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004,S/NZS62368.1(by CB),KC K60950-1(for LRS-100-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9) approved | ||||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB17625 . 1,GB/T 9254 . 1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only) | |||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only) | |||||||
OTHERS | MTBF | 3348.9K hrs min. Telcordia SR-332 (Bellcore) ; 677.4Khrs min. MIL-HDBK-217F (25℃) | ||||||
DIMENSION | 129*97*30mm (L*W*H) | |||||||
PACKING | 0.33Kg ; 40pcs/14.2Kg/0.87CUFT | |||||||
NOTE | 1. AII parameters NOT speciaIIy mentioned are measured at 230VAC input, rated Ioad and 25℃ of ambient temperature. 2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor. 3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation. 4. Line reguIation is measured from Iow Iine to high Iine at rated Ioad. 5. Load reguIation is measured from 0% to 100% rated Ioad. 6. Length of set up time is measured at coId first start. Turning ON/OFF the power suppIy Very quickIy may Iead to increase of the set up time. 7. The ambient temperature derating of 5℃/1000m is needed for operating aItitude greater than 2000m(6500ft). 8. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by mounting the unit on a 360mm*360mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directiVes. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.” 9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. | |||||||
LRS-150
MODEL | LRS-150-12 | LRS-150-15 | LRS-150-24 | LRS-150-36 | LRS-150-48 | ||
OUTPUT | DC VOLTAGE | 12V | 15V | 24V | 36V | 48V | |
RATED CURRENT | 12.5A | 10A | 6.5A | 4.3A | 3.3A | ||
CURRENT RANGE | 0 ~ 12.5A | 0 ~ 10A | 0 ~ 6.5A | 0 ~ 4.3A | 0 ~ 3.3A | ||
RATED POWER | 150W | 150W | 156W | 154.8W | 158.4W | ||
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | 200mVp-p | ||
VOLTAGE ADJ. RANGE | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | ||
VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
LOAD REGULATION Note.5 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||
SETUP, RISE TIME | 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 40ms/230VAC 35ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC) | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 87.5% | 88.5% | 89% | 89% | 90% | ||
AC CURRENT (Typ.) | 3A/115VAC 1.7A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD STAR 60A/230VAC | ||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | ||||||
PROTECTION | OVER LOAD | 110 ~ 140% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 13.8 ~ 16.2V | 18.75 ~ 21.75V | 28.8 ~ 33.6V | 41.4 ~ 48.6V | 55.2 ~ 64.8V | ||
Protection type : Shut down o/p voltage, re-power on to recover | |||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | ||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Refer to "Derating Curve") | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing | ||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||
OVER VOLTAGE CATEGORY | Ⅲ ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters | ||||||
SAFETY&EMC (Note 7) |
SAFETY STANDARDS | UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16 ,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004,KC K60950-1(for LRS-150-12 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9), AS/NZS 62368. 1(by CB) approved | |||||
WITHSTAND VOLTAGE | I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||
EMC EMISSION | Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤75% Load), BS EN/EN61000-3-3,GB17625.1,GB/T 9254.1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only) | ||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only) | ||||||
OTHERS | MTBF | 2707.7K hrs min. Telcordia SR-332 (Bellcore) ; 558.2Khrs min. MIL-HDBK-217F (25℃) | |||||
DIMENSION | 159*97*30mm (L*W*H) | ||||||
PACKING | 0.42Kg ; 30pcs/13.8Kg/0.80CUFT | ||||||
NOTE | 1. AII parameters NOT speciaIIy mentioned are measured at 230VAC input, rated Ioad and 25℃ of ambient temperature. 2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor. 3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation. 4. Line reguIation is measured from Iow Iine to high Iine at rated Ioad. 5. Load reguIation is measured from 0% to 100% rated Ioad. 6. Length of set up time is measured at coId first start. Turning ON/OFF the power suppIy Very quickIy may Iead to increase of the set up time. 7. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by mounting the unit on a 360mm*360mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directiVes. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.” 8. The ambient temperature derating of 5℃/1000m is needed for operating aItitude greater than 2000m (6500ft). 9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. | ||||||
LRS-200
MODEL | LRS-200-3.3 | LRS-200-4.2 | LRS-200-5 | LRS-200-12 | LRS-200-15 | LRS-200-24 | LRS-200-36 | LRS-200-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 40A | 40A | 40A | 17A | 14A | 8.8A | 5.9A | 4.4A | |
CURRENT RANGE | 0 ~ 40A | 0 ~ 40A | 0 ~ 40A | 0 ~ 17A | 0 ~ 14A | 0 ~ 8.8A | 0 ~ 5.9A | 0 ~ 4.4A | |
RATED POWER | 132W | 168W | 200W | 204W | 210W | 211.2W | 212.4W | 211.2W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 2.97 ~ 3.6V | 3.6 ~ 4.4V | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±4.0% | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.5% | ±2.5% | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1500ms, 50ms/230VAC 1500ms,50ms/115VAC at full load | ||||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 12ms/115VAC at full load | ||||||||
INPUT | VOLTAGE RANGE | 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC) | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
EFFICIENCY (Typ.) | 83% | 86% | 87% | 87.5% | 88% | 89.5% | 89.5% | 90% | |
AC CURRENT (Typ.) | 4A/115VAC 2.2A/230VAC | ||||||||
INRUSH CURRENT (Typ.) | COLD STAR 60A/115VAC 60A/230VAC | ||||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||||
PROTECTION |
OVER LOAD | 110 ~ 140% rated output power | |||||||
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | |||||||||
OVER VOLTAGE | 3.8 ~ 4.45V | 4.6 ~ 5.4V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18 ~ 21V | 28.8 ~ 33.6V | 41.4 ~ 46.8V | 55.2 ~ 64.8V | |
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | |||||||||
OVER TEMPERATURE | 3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | ||||||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70℃ (Refer to "Derating Curve") | |||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||
OVER VOLTAGE CATEGORY | Ⅲ: According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters | ||||||||
SAFETY & EMC (Note.9) |
SAFETY STANDARDS | IEC/UL 62368-1, BSMI CNS15598-1,EAC TP TC 004, KC62368-1(for LRS-200-12/24 only),GB 4943 . 1, BIS IS13252(Part1):2010/IEC 60950-1: 2005(NOTE 12) ,BS EN/EN61558-1, BS EN61558-2-16 Designed by AS/NZS 61558 . 1/2 .16, AS/NZS 62368 . 1,BS EN/EN62368-1 | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||||||||
EMC EMISSION | Compliance to BSMI CNS15936, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-200-12/24 only) | ||||||||
EMC IMMUNITY | Compliance to BS EN/EN55035, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-200-12/24 only) | ||||||||
OTHERS | MTBF | 2346.6K hrs min. Telcordia SR-332 (Bellcore) ; 279.4Khrs min. MIL-HDBK-217F (25℃) | |||||||
DIMENSION | 215* 115*30mm (L*W*H) | ||||||||
PACKING | 0.66Kg; 15pcs/10.9Kg/0.67CUFT | ||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 7. The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-200 will enter hiccup mode if the peak load is delivered for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC). 8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft). 9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMI testing of component power supplies.” 10. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W 11. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417. 1. 12. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. | ||||||||
LRS-300
MODEL | LRS-300-5 | LRS-300-12 | LRS-300-24 | LRS-300-48 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 24V | 48V |
RATED CURRENT | 60A | 25A | 12.5A | 6.25A | |
CURRENT RANGE | 0 ~ 60A | 0 ~ 25A | 0 ~ 12.5A | 0 ~ 6.25A | |
RATED POWER | 300W | 300W | 300W | 300W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 21.6 ~ 28.8V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±1.5% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1500ms,50ms/230VAC 1500ms,50ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 16ms/230VAC 12ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 90 ~ 132VAC / 180 ~ 264VAC (selected by switch) /240 ~ 370VDC (switch on 230VAC) | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 83.5% | 85% | 88% | 89% | |
AC CURRENT (Typ.) | 6.8A/115VAC 3.4A/230VAC | ||||
INRUSH CURRENT (Typ.) | 60A/115VAC 60A/230VAC | ||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||
PROTECTION |
OVER LOAD | 110 ~ 140% rated output power | |||
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | |||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 28.8 ~ 33.6V | 55.2 ~ 64.8V | |
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | |||||
OVER TEMPERATURE | 3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | ||||
FUNCTION | FAN ON/OFF CONTROL (Typ.) | RTH3≥50℃ FAN ON, ≤40℃ FAN OFF | |||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70℃ (Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20 ~ 90% RH,non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃,10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||
OVER VOLTAGE CATEGORY | Certified to IEC/UL 62368-1, BSMI CNS 14336-1, BS EN/EN 60335-1, EAC TP TC 004, KC K60950-1 (for LRS-350-12/24 only), AS/NZS 62368.1, and BIS IS 13252 (Part 1): 2010/IEC 60950-1: 2005; Designed in accordance with BS EN/EN 62368-1. | ||||
SAFETY & EMC(Note9) |
SAFETY STANDARDS | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
WITHSTAND VOLTAGE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/ 25℃/ 70% RH | ||||
ISOLATION RESISTANCE | Complies with BSMI CNS13438, EAC TP TC 020, KC KN32, KN35 (LRS-350-12/24 only) | ||||
EMC EMISSION | Complies with EAC TP TC 020,KC KN32,KN35(onlyLRS-350-12/24 ) | ||||
EMC IMMUNITY | ≥327.9K hrs. MIL-HDBK-217F (25℃) | ||||
OTHERS | MTBF | 215*115*30mm (L*W*H) | |||
DIMENSION | 0.76Kg;15pcs/12.4Kg/0.78CUFT | ||||
NOTE | 1.Unless otherwise specified, all specification parameters are measured at an input of 230VAC, rated load, and an ambient temperature of 25℃. 2. Ripple and Noise Measurement Method: Use a 12* twisted pair cable, connect 0.1µF and 47µF capacitors in parallel at the terminal simultaneously, and perform the measurement with a bandwidth of 20MHz. 3. Accuracy: Including setting error, line regulation, and load regulation. 4. Line Regulation Measurement Method: Test from low voltage to high voltage under rated load. 5. Load Regulation Measurement Method: Test from 0% to 100% of the rated load. 6. The start-up time is measured under cold start conditions; frequent and rapid switching on and off may increase the start-up time. 7. For 12V-48V models, the 150% peak load capacity is based on a duration of up to 1 second. If the peak load lasts more than 1 second, the LRS-350 will enter burst mode and resume normal operation once the current is adjusted back to the rated current. 8. When the operating altitude is above 2000 meters (6500 feet), the operating environment temperature shall be derated by 5℃ per 1000 meters. 9. This power supply does not comply with the harmonic current requirements specified in EN61000-3-2. 10. Do not use this power supply under the following conditions: a) The end equipment is used within the European Union; b) The end equipment is connected to a public mains power supply with a rated nominal voltage of 220Vac or higher; c) The power supply is: Installed in end equipment with an average continuous input power greater than 75W and is part of a lighting system. 11. Exceptions: Power supplies used in the following end equipment are not required to meet EN61000-3-2: a) Professional equipment with a total rated input power greater than 1000W; b) Symmetric controlled heating elements with a rated power less than or equal to 200W. | ||||
LRS-350
MODEL | LRS-350-3.3 | LRS-350-4.2 | LRS-350-5 | LRS-350-12 | LRS-350-15 | LRS-350-24 | LRS-350-36 | LRS-350-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 60A | 60A | 60A | 29A | 23.2A | 14.6A | 9.7A | 7.3A | |
CURRENT RANGE | 0 ~ 60A | 0 ~ 60A | 0 ~ 60A | 0 ~ 29A | 0 ~ 23.2A | 0 ~ 14.6A | 0 ~ 9.7A | 0 ~ 7.3A | |
RATED POWER | 198W | 252W | 300W | 348W | 348W | 350.4W | 349.2W | 350.4W | |
RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 2.97 ~ 3.6V | 3.6 ~ 4.4V | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±4.0% | ±4.0% | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.5% | ±2.5% | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1500ms, 50ms/230VAC 1500ms,50ms/115VAC at full load | ||||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 12ms/115VAC at full load | ||||||||
INPUT | VOLTAGE RANGE | 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (switch on 230VAC) | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
EFFICIENCY (Typ.) | 79.5% | 81.5% | 83.5% | 85% | 86% | 88% | 88.5% | 89% | |
AC CURRENT (Typ.) | 6.8A/115VAC 3.4A/230VAC | ||||||||
INRUSH CURRENT (Typ.) | 60A/115VAC 60A/230VAC | ||||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||||
PROTECTION |
OVER LOAD | 110 ~ 140% rated output power | |||||||
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | |||||||||
OVER VOLTAGE | 3.8 ~ 4.45V | 4.6 ~ 5.4V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18 ~ 21V | 28.8 ~ 33.6V | 41.4 ~ 46.8V | 55.2 ~ 64.8V | |
3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | |||||||||
OVER TEMPERATURE | 3.3~36V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover. | ||||||||
FUNCTION | FAN ON/OFF CONTROL (Typ.) | RTH3≥50℃ FAN ON, ≤40℃ FAN OFF | |||||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70℃ (Refer to "Derating Curve") | |||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | ||||||||
OVER VOLTAGE CATEGORY | Ⅲ: According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters | ||||||||
SAFETY & EMC(Note9) |
SAFETY STANDARDS | IEC/UL 62368-1,BSMI CNS15598-1,EAC TP TC 004,KC62368-1(for LRS-350-12/24 only),GB 4943.1, BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 12),BS EN/EN61558-1, BS EN61558-2-16 Designed by AS/NZS 61558. 1/2.16, AS/NZS 62368.1,BS EN/EN62368-1, | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH | ||||||||
EMC EMISSION | Compliance to BSMI CNS15936, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-350-12/24 only) | ||||||||
EMC IMMUNITY | Compliance to BS EN/EN55035, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-350-12/24 only) | ||||||||
OTHERS | MTBF | 2099.9K hrs min. Telcordia SR-332 (Bellcore) ; 328.6Khrs min. MIL-HDBK-217F (25℃) | |||||||
DIMENSION | 215* 115*30mm (L*W*H) | ||||||||
PACKING | 0.76Kg; 15pcs/12.4Kg/0.67CUFT | ||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. 7. The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-350 will enter hiccup mode if the peak load is delivered for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC). 8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft). 9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMI testing of component power supplies.” 10. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W 11. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417. 1. 12. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information. | ||||||||
Note:Inquiry for details.
Company Advantages
1.Refined Operations
A rigorous quality management system ensures products are delivered in one step, giving you a head start.
2.Strict Quality Inspection Process
Rapid production with guaranteed quality, creating reliable products for your peace of mind.
3.Comprehensive Warehouse Inventory
A complete range of product models for fast delivery.
4.Independent Innovation