HaloCore Control
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation
  • LRS Series Power Supply Industrial Switching Power Supply for LED & Automation

LRS Series Power Supply Industrial Switching Power Supply for LED & Automation

Reliable LRS series power supply converts 220V AC to stable 24V/12V DC for industrial and LED applications.

Model:
LRS-35-12 12V3A
LRS-35-24 24V1.5A
LRS-50-12 12V4.2A
LRS-50-24 24V2.2A
LRS-75-12 12V6A
LRS-75-24 24V3.2A
LRS-100-12 12V8.5A
LRS-100-24 24V4.5A
LRS-120-12 12V10A
LRS-120-24 24V5A
LRS-150-12 12V12.5A
LRS-150-24 24V6.5A
LRS-200-12 12V17A
LRS-200-24 24V8.8A
LRS-250-12 12V20A
LRS-250-24 24V10A
LRS-350-12 12V29A
LRS-350-24 24V14.6A
LRS-350-48 48V7.3A
LRS-400-12 12V33A
LRS-400-24 24V16.7A
White LRS-450-12 12V37.5A
Off-White LRS-450-24 24V19A
Cream White LRS-500-12 12V41A
Light Gray LRS-500-24 24V20A
Dark Gray LRS-600-24 24V25A
Red LRS-35-5 5V7A
Lotus Root LRS-50-5 5V10A
Wine Red LRS-75-5 5V12A
Watermelon Red LRS-100-5 5V20A
Khaki LRS-120-5 5V20A
Ginger Yellow LRS-150-5 5V30A
Bright Yellow LRS-200-5 5V40A
Apricot LRS-250-5 5V50A
Gold LRS-350-5 5V60A
Yellow LRS-450-36 36V12.5A
Blue LRS-450-48 48V10A
Purple LRS-500-36 36V13.9A
Maroon LRS-500-48 48V10A
Brown LRS-600-36 36V16.6A
Camel LRS-600-48 48V12.5A
Inquiry for customization 5V/36V/48V

USD 4.23

output value: Monthly Output500

contact shop

Product Description

The LRS Series is a compact and cost-effective industrial switching power supply designed to convert 220V AC input into stable 24V or 12V DC output. It meets diverse power requirements for automation equipment, LED lighting, control systems, and industrial machinery. Built with high-quality components, it ensures high efficiency up to 90%, low ripple noise, and full protection against overload, overvoltage, and short circuit. Its lightweight metal housing and screw terminal design allow for easy installation and long-term durability in demanding environments.

Functional Features








                                                                FULL POWER                           MULTIPLE PROTECTION            STABLE PERFORMANCE


                                                 PURE COPPER TRANSFORMER                  IMPORTED CHIP                          DIRECT DEAL



Full Power

Brings a Brand-New Experience

Strong Power, up to 500W

Durable Output

More Stable Operation


Powerful Heat Dissipation

Rapid CoolingTwo distinct heat dissipation modes are available: fan cooling and honeycomb structure cooling, effectively protecting internal components.



Dust Cover Design

Safety Design

Junction box protective cover reduces dust ingress, prevents accidental contact,and enhances operational safety.


Product Views

  1. Stable Performance

    Full power, stable performance, high-frequency transformer

  2. Multiple Intelligent Protection.

    Built-in intelligent protection system, effectively safeguards against safety hazards.

  3. Wiring Diagram

    Easy Wiring, bringing you closer to a better understanding of our products.

    ①Neutral Input

    Line Input

    Earth Wire

    Output Negative

    Output Positive

    Adjustable Potentiometer

1.

                                                                                                                                    Overvoltage Protection




                                                                                                                                                                       Overload Protection




                                                                                                                                                                        Short Circuit Protection




                                                                                                                                                                        Overtemperature Protection


2.


                                                                                                                               High-quality electrolytic capacitors





High-frequency copper-core transformer



3.

Application

With industrial-grade quality and high-quality components, the LRS series ultra-thin switching power supply has a wide range of applications. It can stably adapt to monitoring equipment, providing continuous and reliable power support for security monitoring systems to ensure 24-hour normal operation of the equipment. At the same time, it is suitable for medical equipment and automatic control equipment, meeting the strict requirements of such precision equipment for power supply stability. In addition, it can also be applied to urban lighting projects, providing safe and stable power supply for various lighting fixtures, and can also adapt to various industrial control equipment, helping industrial production operate efficiently. With its stable performance and wide adaptability, this power supply has become the preferred power supply equipment in many fields.

Product parameters

LRS-35

MODEL

LRS-35-5

LRS-35-12

LRS-35-15

LRS-35-24

LRS-35-36

LRS-35-48

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

36V

48V

RATED CURRENT

7A

3A

2.4A

1.5A

1A

0.8A

CURRENT RANGE

0 ~ 7A

0 ~ 3A

0 ~ 2.4A

0 ~ 1.5A

0 ~ 1A

0 ~ 0.8A

RATED POWER

35W

36W

36W

36W

36W

38.4W

RIPPLE & NOISE (max.) Note.2

80mVp-p

120mVp-p

120mVp-p

150mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

4.5 ~ 5.5V

10.2 ~ 13.8V

13.5 ~ 18V

21.6 ~ 28.8V

32.4 ~ 39.6V

43.2 ~ 52.8V

VOLTAGE TOLERANCE  Note.3

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION   Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

1000ms, 30ms/230VAC        2000ms,30ms/115VAC at full load

HOLD UP TIME (Typ.)

30ms/230VAC      12ms/115VAC at full load

INPUT

VOLTAGE RANGE

85 ~ 264VAC          120 ~ 373VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

82%

86%

86%

88%

88%

89%

AC CURRENT (Typ.)

0.7A/115VAC        0.42A/230VAC

INRUSH CURRENT (Typ.)

COLD START 45A/230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

PROTECTION

OVER LOAD

110 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~ 6.9V

13.8 ~ 16.2V

18.75 ~ 21.75V

28.8 ~ 33.6V

41.4 ~ 48.6V

55.2 ~ 64.8V

Protection type : Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.

-30 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

OVER VOLTAGE CATEGORY

Ⅲ; According to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters


 

SAFETY STANDARDS

UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16 ,GB 4943.1,

BSMI CNS15598-1, EAC TP TC 004,AS/NZS 60950. 1(by CB),KC K60950-1(for LRS-35-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 10) approved

SAFETY &

EMC(Note9)

WITHSTAND VOLTAGE

I/P-O/P:4KVAC     I/P-FG:2KVAC     O/P-FG:1.25KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to BS EN/EN55032 (CISPR32) Class B , BS EN/EN55014 , BS EN/EN61000-3-2 ,-3 ,

GB17625 . 1 ,GB/T 9254 . 1 , BSMI CNS15936 , EAC TP TC 020 ,KC KN32 ,KN35(for LRS-35-12/24 only)

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8, 11, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN55035, heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-35-12/24 only)

OTHERS

MTBF

3201.5K hrs min.      Telcordia SR-332 (Bellcore) ;  655.5Khrs min.      MIL-HDBK-217F (25℃)

DIMENSION

99*82*30mm (L*W*H)

PACKING

0.21Kg ; 60pcs/14Kg/0.93CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Line regulation is measured from low line to high line at rated load.

5. Load regulation is measured from 0% to 100% rated load.

6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

7. 5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications.

8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).

9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by

mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMI testing of component power supplies.”

10. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.


LRS-50

MODEL

LRS-50-3.3

LRS-50-5

LRS-50-12

LRS-50-15

LRS-50-24

LRS-50-36

LRS-50-48

OUTPUT

DC VOLTAGE

3.3V

5V

12V

15V

24V

36V

48V

RATED CURRENT

10A

10A

4.2A

3.4A

2.2A

1.45A

1.1A

CURRENT RANGE

0 ~ 10A

0 ~ 10A

0 ~ 4.2A

0 ~ 3.4A

0 ~ 2.2A

0 ~ 1.45A

0 ~ 1.1A

RATED POWER

33W

50W

50.4W

51W

52.8W

52.2W

52.8W

RIPPLE & NOISE (max.) Note.2

80mVp-p

80mVp-p

120mVp-p

120mVp-p

150mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

2.97 ~ 3.6V

4.5 ~ 5.5V

10.2 ~ 13.8V

13.5 ~ 18V

21.6 ~ 28.8V

32.4 ~ 39.6V

43.2 ~ 52.8V

VOLTAGE TOLERANCE  Note.3

±3.0%

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION   Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±2.0%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

1000ms, 30ms/230VAC        2000ms,30ms/115VAC at full load

HOLD UP TIME (Typ.)

30ms/230VAC      12ms/115VAC at full load

INPUT

VOLTAGE RANGE

85 ~ 264VAC          120 ~ 373VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

80%

83%

86%

88%

88%

89%

90%

AC CURRENT (Typ.)

0.95A/115VAC        0.56A/230VAC

INRUSH CURRENT (Typ.)

COLD START 45A/230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

PROTECTION

OVER LOAD

110 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

3.8 ~ 4.45V

5.9~ 7.3V

13.8 ~ 17.2V

18.75 ~ 25.75V

28.8 ~ 36.6V

41.4 ~ 51.6V

55.2 ~ 67.8V

Protection type : Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.

-30 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

OVER VOLTAGE CATEGORY

Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters

SAFETY &

EMC

(Note 9)

 

SAFETY STANDARDS

UL62368-1 , TUV BS EN/EN62368-1 , BS EN/EN60335-1 , BS EN/EN61558-1/-2-16 ,GB 4943 . 1 ,

BSMI CNS15598-1 , EAC TP TC 004 , AS/NZS 60950 . 1(by CB) ,KC K60950-1(for LRS-50-12/24 only) , BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 10) approved

WITHSTAND VOLTAGE

I/P-O/P:4KVAC     I/P-FG:2KVAC     O/P-FG:1.25KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3,

GB17625 . 1,GB/T 9254 . 1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only)

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level, EAC TP TC 020,KC KN32,KN35(for LRS-50-12/24 only)

OTHERS

MTBF

3149.8K hrs min.      Telcordia SR-332 (Bellcore) ;   561.6Khrs min.      MIL-HDBK-217F (25℃)

DIMENSION

99*82*30mm (L*W*H)

PACKING

0.21Kg; 60pcs/14Kg/0.93CUFT

NOTE

1. AII parameters NOT speciaIIy mentioned are measured at 230vAC input, rated Ioad and 25℃ of ambient temperature.

2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor.

3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation.

4. Line reguIation is measured from Iow Iine to high Iine at rated Ioad.

5. Load reguIation is measured from 0% to 100% rated Ioad.

6. Length of set up time is measured at coId first start. Turning ON/OFF the power suppIy Very quickIy may Iead to increase of the set up time.

7. 3.3v,5v when the Ioad factor 0~50%, the switching power Iess is reduced by burst operation, which wiII cause rippIe and rippIe noise to go beyond the specifications.

8. The ambient temperature derating of 5℃/1000m is needed for operating aItitude greater than 2000m(6500ft).

9. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by

mounting the unit on a 360mm*360mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directiVes. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.”

10. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.


LRS-75

MODEL

LRS-75-5

LRS-75-12

LRS-75-15

LRS-75-24

LRS-75-36

LRS-75-48

OUTPUT

DC VOLTAGE

5V

12V

15V

24V

36V

48V

RATED CURRENT

14A

6A

5A

3.2A

2.1A

1.6A

CURRENT RANGE

0 ~ 14A

0 ~ 6A

0 ~ 5A

0 ~ 3.2A

0 ~ 2.1A

0 ~ 1.6A

RATED POWER

70W

72W

75W

76.8W

75.6W

76.8W

RIPPLE & NOISE (max.) Note.2

100mVp-p

120mVp-p

120mVp-p

150mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

4.5 ~ 5.5V

10.2 ~ 13.8V

13.5 ~ 18V

21.6 ~ 28.8V

32.4 ~ 39.6V

43.2 ~ 52.8V

VOLTAGE TOLERANCE  Note.3

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION   Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

500ms, 30ms/230VAC       500ms,30ms/115VAC  at full load

HOLD UP TIME (Typ.)

60ms/230VAC      12ms/115VAC at full load

INPUT

VOLTAGE RANGE

85 ~ 264VAC          120 ~ 373VDC

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

86.5%

89%

89%

90%

91.5%

91.5%

AC CURRENT (Typ.)

1.4A/115VAC        0.85A/230VAC

INRUSH CURRENT (Typ.)

COLD START 65A/230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

PROTECTION

OVER LOAD

110 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

5.75 ~ 6.75V

13.8 ~ 16.2V

18.75 ~ 21.75V

28.8 ~ 33.6V

41.4 ~ 48.6V

55.2 ~ 64.8V

Protection type : Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.

-30 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

OVER VOLTAGE CATEGORY

Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178,BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters

SAFETY&

EMC

(Note 8)

 

SAFETY STANDARDS

UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004,AS/NZS 62368.1(by CB),KC62368-1,

BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9) approved

WITHSTAND VOLTAGE

I/P-O/P:4KVAC     I/P-FG:2KVAC     O/P-FG:1.25KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB17625 . 1,GB/T 9254 . 1, BSMI CNS15936, EAC TP TC 020,KC KSC 9832, KSC 9835

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8, 11, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN55035, heavy industry level,EAC TP TC 020,KC KSC 9832, KSC 9835

OTHERS

MTBF

3334.3K hrs min.      Telcordia SR-332 (Bellcore) ;  667.2Khrs min.      MIL-HDBK-217F (25℃)

DIMENSION

99*97*30mm (L*W*H)

PACKING

0.23Kg ; 45pcs/ 11.5Kg/ 0.77CUFT

NOTE

1. AII parameters NOT speciaIIy mentioned are measured at 230VAC input, rated Ioad and 25℃ of ambient temperature.

2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor.

3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation.

4. Line reguIation is measured from Iow Iine to high Iine at rated Ioad.

5. Load reguIation is measured from 0% to 100% rated Ioad.

6. Length of set up time is measured at coId first start. Turning ON/OFF the power suppIy Very quickIy may Iead to increase of the set up time.

7. The ambient temperature derating of 5℃/1000m is needed for operating aItitude greater than 2000m(6500ft).

8. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by

mounting the unit on a 360mm*360mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directiVes. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.”

9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.


LRS-100

MODEL

LRS-100-3.3

LRS-100-5

LRS-100-12

LRS-100-15

LRS-100-24

LRS-100-36

LRS-100-48

OUTPUT

DC VOLTAGE

3.3V

5V

12V

15V

24V

36V

48V

RATED CURRENT

20A

18A

8.5A

7A

4.5A

2.8A

2.3A

CURRENT RANGE

0 ~ 20A

0 ~ 18A

0 ~ 8.5A

0 ~ 7A

0 ~ 4.5A

0 ~ 2.8A

0 ~ 2.3A

RATED POWER

66W

90W

102W

105W

108W

100.8W

110.4W

RIPPLE & NOISE (max.) Note.2

100mVp-p

100mVp-p

120mVp-p

120mVp-p

150mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

2.97 ~ 3.6V

4.5 ~ 5.5V

10.2 ~ 13.8V

13.5 ~ 18V

21.6 ~ 28.8V

32.4 ~ 39.6V

43.2 ~ 52.8V

VOLTAGE TOLERANCE  Note.3

±3.0%

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION   Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±2.0%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

500ms, 30ms/230VAC       500ms,30ms/115VAC  at full load

HOLD UP TIME (Typ.)

55ms/230VAC      10ms/115VAC at full load

INPUT

VOLTAGE RANGE

85 ~ 264VAC          120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

84.5%

86%

88%

88.5%

90%

90.5%

91%

AC CURRENT (Typ.)

1.9A/115VAC          1.2A/230VAC

INRUSH CURRENT (Typ.)

COLD START 50A/230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

PROTECTION

OVER LOAD

110 ~ 150% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

3.8 ~ 4.45V

5.75 ~ 6.75V

13.8 ~ 16.2V

18.75 ~ 21.75V

28.8 ~ 33.6V

41.4 ~ 48.6V

55.2 ~ 64.8V

Protection type : Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.

-30 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

OVER VOLTAGE CATEGORY

Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters

SAFETY &

EMC

(Note 8)

 

SAFETY STANDARDS

UL 62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,GB 4943.1,

BSMI CNS15598-1, EAC TP TC 004,S/NZS62368.1(by CB),KC K60950-1(for LRS-100-12/24 only), BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9) approved

WITHSTAND VOLTAGE

I/P-O/P:4KVAC     I/P-FG:2KVAC     O/P-FG:1.25KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3,

GB17625 . 1,GB/T 9254 . 1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level,  EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)

OTHERS

MTBF

3348.9K hrs min.      Telcordia SR-332 (Bellcore) ;  677.4Khrs min.      MIL-HDBK-217F (25℃)

DIMENSION

129*97*30mm (L*W*H)

PACKING

0.33Kg ; 40pcs/14.2Kg/0.87CUFT

NOTE

1. AII parameters NOT speciaIIy mentioned are measured at 230VAC input, rated Ioad and 25℃ of ambient temperature.

2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor.

3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation.

4. Line reguIation is measured from Iow Iine to high Iine at rated Ioad.

5. Load reguIation is measured from 0% to 100% rated Ioad.

6. Length of set up time is measured at coId first start. Turning ON/OFF the power suppIy Very quickIy may Iead to increase of the set up time.

7. The ambient temperature derating of 5℃/1000m is needed for operating aItitude greater than 2000m(6500ft).

8. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by

mounting the unit on a 360mm*360mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directiVes. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.”

9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.


LRS-150

MODEL

LRS-150-12

LRS-150-15

LRS-150-24

LRS-150-36

LRS-150-48

OUTPUT

DC VOLTAGE

12V

15V

24V

36V

48V

RATED CURRENT

12.5A

10A

6.5A

4.3A

3.3A

CURRENT RANGE

0 ~ 12.5A

0 ~ 10A

0 ~ 6.5A

0 ~ 4.3A

0 ~ 3.3A

RATED POWER

150W

150W

156W

154.8W

158.4W

RIPPLE & NOISE (max.) Note.2

150mVp-p

150mVp-p

200mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

10.2 ~ 13.8V

13.5 ~ 18V

21.6 ~ 28.8V

32.4 ~ 39.6V

43.2 ~ 52.8V

VOLTAGE TOLERANCE  Note.3

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION   Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

500ms, 30ms/230VAC       500ms,30ms/115VAC  at full load

HOLD UP TIME (Typ.)

40ms/230VAC     35ms/115VAC at full load

INPUT

VOLTAGE RANGE

85 ~ 132VAC / 170 ~ 264VAC by switch           240 ~ 370VDC(switch on 230VAC)

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

87.5%

88.5%

89%

89%

90%

AC CURRENT (Typ.)

3A/115VAC          1.7A/230VAC

INRUSH CURRENT (Typ.)

COLD STAR 60A/230VAC

LEAKAGE CURRENT

<0.75mA / 240VAC

PROTECTION

OVER LOAD

110 ~ 140% rated output power

Protection type : Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

13.8 ~ 16.2V

18.75 ~ 21.75V

28.8 ~ 33.6V

41.4 ~ 48.6V

55.2 ~ 64.8V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.

-30 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH non-condensing

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

OVER VOLTAGE CATEGORY

Ⅲ ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters

SAFETY&EMC

(Note 7)

 

SAFETY STANDARDS

UL62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16 ,GB 4943.1, BSMI CNS15598-1, EAC TP TC 004,KC K60950-1(for LRS-150-12 only),

BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 9), AS/NZS 62368. 1(by CB) approved

WITHSTAND VOLTAGE

I/P-O/P:4KVAC     I/P-FG:2KVAC     O/P-FG:1.25KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2 Class A(≤75% Load),

BS EN/EN61000-3-3,GB17625.1,GB/T 9254.1, BSMI CNS15936, EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only)

EMC IMMUNITY

Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level,  EAC TP TC 020,KC KN32,KN35(for LRS-150-12 only)

OTHERS

MTBF

2707.7K hrs min.      Telcordia SR-332 (Bellcore) ;   558.2Khrs min.      MIL-HDBK-217F (25℃)

DIMENSION

159*97*30mm (L*W*H)

PACKING

0.42Kg ; 30pcs/13.8Kg/0.80CUFT

NOTE

1. AII parameters NOT speciaIIy mentioned are measured at 230VAC input, rated Ioad and 25℃ of ambient temperature.

2. RippIe & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf paraIIeI capacitor.

3. ToIerance : incIudes set up toIerance, Iine reguIation and Ioad reguIation.

4. Line reguIation is measured from Iow Iine to high Iine at rated Ioad.

5. Load reguIation is measured from 0% to 100% rated Ioad.

6. Length of set up time is measured at coId first start. Turning ON/OFF the power suppIy Very quickIy may Iead to increase of the set up time.

7. The power suppIy is considered a component which wiII be instaIIed into a finaI equipment. AII the EMC tests are been executed by

mounting the unit on a 360mm*360mm metaI pIate with 1mm of thickness. The finaI equipment must be re-confirmed that it stiII meets EMC directiVes. For guidance on how to perform these EMC tests, pIease refer to “EMI testing of component power suppIies.”

8. The ambient temperature derating of 5℃/1000m is needed for operating aItitude greater than 2000m (6500ft).

9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.


LRS-200

MODEL

LRS-200-3.3

LRS-200-4.2

LRS-200-5

LRS-200-12

LRS-200-15

LRS-200-24

LRS-200-36

LRS-200-48

OUTPUT

DC VOLTAGE

3.3V

4.2V

5V

12V

15V

24V

36V

48V

RATED CURRENT

40A

40A

40A

17A

14A

8.8A

5.9A

4.4A

CURRENT RANGE

0 ~ 40A

0 ~ 40A

0 ~ 40A

0 ~ 17A

0 ~ 14A

0 ~ 8.8A

0 ~ 5.9A

0 ~ 4.4A

RATED POWER

132W

168W

200W

204W

210W

211.2W

212.4W

211.2W

RIPPLE & NOISE (max.) Note.2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

2.97 ~ 3.6V

3.6 ~ 4.4V

4.5 ~ 5.5V

10.2 ~ 13.8V

13.5 ~ 18V

21.6 ~ 28.8V

32.4 ~ 39.6V

43.2 ~ 52.8V

VOLTAGE TOLERANCE  Note.3

±3.0%

±4.0%

±3.0%

±1.5%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION   Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±2.5%

±2.5%

±2.0%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

1500ms, 50ms/230VAC         1500ms,50ms/115VAC  at full load

HOLD UP TIME (Typ.)

16ms/230VAC      12ms/115VAC at full load

INPUT

VOLTAGE RANGE

90 ~ 132VAC / 180 ~ 264VAC by switch          240 ~ 370VDC      (switch on 230VAC)

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

83%

86%

87%

87.5%

88%

89.5%

89.5%

90%

AC CURRENT (Typ.)

4A/115VAC        2.2A/230VAC

INRUSH CURRENT (Typ.)

COLD STAR 60A/115VAC         60A/230VAC

LEAKAGE CURRENT

<2mA / 240VAC

PROTECTION

 

OVER LOAD

110 ~ 140% rated output power

3.3~36V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

 

OVER VOLTAGE

3.8 ~ 4.45V

4.6 ~ 5.4V

5.75 ~ 6.75V

13.8 ~ 16.2V

18 ~ 21V

28.8 ~ 33.6V

41.4 ~ 46.8V

55.2 ~ 64.8V

3.3~36V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

OVER TEMPERATURE

3.3~36V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

ENVIRONMENT

WORKING TEMP.

-25 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

OVER VOLTAGE CATEGORY

Ⅲ: According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters

SAFETY &

EMC

(Note.9)

 

SAFETY STANDARDS

IEC/UL 62368-1, BSMI CNS15598-1,EAC TP TC 004, KC62368-1(for LRS-200-12/24 only),GB 4943 . 1, BIS IS13252(Part1):2010/IEC 60950-1: 2005(NOTE 12) ,BS EN/EN61558-1, BS EN61558-2-16

Designed by AS/NZS 61558 . 1/2 .16, AS/NZS 62368 . 1,BS EN/EN62368-1

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to BSMI CNS15936, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-200-12/24 only)

EMC IMMUNITY

Compliance to BS EN/EN55035, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-200-12/24 only)

OTHERS

MTBF

2346.6K hrs min.      Telcordia SR-332 (Bellcore) ;   279.4Khrs min.      MIL-HDBK-217F (25℃)

DIMENSION

215* 115*30mm (L*W*H)

PACKING

0.66Kg; 15pcs/10.9Kg/0.67CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Line regulation is measured from low line to high line at rated load.

5. Load regulation is measured from 0% to 100% rated load.

6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

7. The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-200 will enter hiccup mode if the peak load is delivered for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC).

8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).

9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by

mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMI testing of component power supplies.”

10. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions:

a) the end-devices is used within the European Union, and

b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and

c) the power supply is:

- installed in end-devices with average or continuous input power greater than 75W, or

- belong to part of a lighting system

Exception:

Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2

a) professional equipment with a total rated input power greater than 1000W;

b) symmetrically controlled heating elements with a rated power less than or equal to 200W

11. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417. 1.

12. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.


LRS-300

MODEL

LRS-300-5

LRS-300-12

LRS-300-24

LRS-300-48

OUTPUT

DC VOLTAGE

5V

12V

24V

48V

RATED CURRENT

60A

25A

12.5A

6.25A

CURRENT RANGE

0 ~ 60A

0 ~ 25A

0 ~ 12.5A

0 ~ 6.25A

RATED POWER

300W

300W

300W

300W

RIPPLE & NOISE (max.) Note.2

150mVp-p

150mVp-p

150mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

4.5 ~ 5.5V

10.2 ~ 13.8V

21.6 ~ 28.8V

43.2 ~ 52.8V

VOLTAGE TOLERANCE  Note.3

±3.0%

±1.5%

±1.0%

±1.0%

LINE REGULATION   Note.4

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±2.0%

±1.0%

±0.5%

±0.5%

SETUP, RISE TIME

1500ms,50ms/230VAC 1500ms,50ms/115VAC  at full load

HOLD UP TIME (Typ.)

16ms/230VAC 12ms/115VAC  at full load

INPUT

VOLTAGE RANGE

90 ~ 132VAC / 180 ~ 264VAC (selected by switch) /240 ~ 370VDC (switch on 230VAC)

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

83.5%

85%

88%

89%

AC CURRENT (Typ.)

6.8A/115VAC 3.4A/230VAC

INRUSH CURRENT (Typ.)

60A/115VAC 60A/230VAC

LEAKAGE CURRENT

<2mA / 240VAC

PROTECTION

 

OVER LOAD

110 ~ 140% rated output power

3.3~36V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

 

OVER VOLTAGE

5.75 ~ 6.75V

13.8 ~ 16.2V

28.8 ~ 33.6V

55.2 ~ 64.8V

3.3~36V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

OVER TEMPERATURE

3.3~36V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

FUNCTION

FAN ON/OFF CONTROL (Typ.)

RTH3≥50℃ FAN ON, ≤40℃ FAN OFF

ENVIRONMENT

WORKING TEMP.

-25 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH,non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃,10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

OVER VOLTAGE CATEGORY

Certified to IEC/UL 62368-1, BSMI CNS 14336-1, BS EN/EN 60335-1, EAC TP TC 004, KC K60950-1 (for LRS-350-12/24 only), AS/NZS 62368.1, and BIS IS 13252 (Part 1): 2010/IEC 60950-1: 2005; Designed in accordance with BS EN/EN 62368-1.

SAFETY & EMC(Note9)

 

SAFETY STANDARDS

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

WITHSTAND VOLTAGE

I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/ 25℃/ 70% RH

ISOLATION RESISTANCE

Complies with BSMI CNS13438, EAC TP TC 020, KC KN32, KN35 (LRS-350-12/24 only)

EMC EMISSION

Complies with EAC TP TC 020,KC KN32,KN35(onlyLRS-350-12/24 )

EMC IMMUNITY

≥327.9K hrs. MIL-HDBK-217F (25℃)

OTHERS

MTBF

215*115*30mm (L*W*H)

DIMENSION

0.76Kg;15pcs/12.4Kg/0.78CUFT

NOTE

1.Unless otherwise specified, all specification parameters are measured at an input of 230VAC, rated load, and an ambient temperature of 25℃.

2. Ripple and Noise Measurement Method: Use a 12* twisted pair cable, connect 0.1µF and 47µF capacitors in parallel at the terminal simultaneously, and perform the measurement with a bandwidth of 20MHz.

3. Accuracy: Including setting error, line regulation, and load regulation.

4. Line Regulation Measurement Method: Test from low voltage to high voltage under rated load.

5. Load Regulation Measurement Method: Test from 0% to 100% of the rated load.

6. The start-up time is measured under cold start conditions; frequent and rapid switching on and off may increase the start-up time.

7. For 12V-48V models, the 150% peak load capacity is based on a duration of up to 1 second. If the peak load lasts more than 1 second, the LRS-350 will enter burst mode and resume normal operation once the current is adjusted back to the rated current.

8. When the operating altitude is above 2000 meters (6500 feet), the operating environment temperature shall be derated by 5℃ per 1000 meters.

9. This power supply does not comply with the harmonic current requirements specified in EN61000-3-2.

10. Do not use this power supply under the following conditions:

a) The end equipment is used within the European Union;

b) The end equipment is connected to a public mains power supply with a rated nominal voltage of 220Vac or higher;

c) The power supply is:

Installed in end equipment with an average continuous input power greater than 75W and is part of a lighting system.

11. Exceptions:

Power supplies used in the following end equipment are not required to meet EN61000-3-2:

a) Professional equipment with a total rated input power greater than 1000W;

b) Symmetric controlled heating elements with a rated power less than or equal to 200W.


LRS-350

MODEL

LRS-350-3.3

LRS-350-4.2

LRS-350-5

LRS-350-12

LRS-350-15

LRS-350-24

LRS-350-36

LRS-350-48

OUTPUT

DC VOLTAGE

3.3V

4.2V

5V

12V

15V

24V

36V

48V

RATED CURRENT

60A

60A

60A

29A

23.2A

14.6A

9.7A

7.3A

CURRENT RANGE

0 ~ 60A

0 ~ 60A

0 ~ 60A

0 ~ 29A

0 ~ 23.2A

0 ~ 14.6A

0 ~ 9.7A

0 ~ 7.3A

RATED POWER

198W

252W

300W

348W

348W

350.4W

349.2W

350.4W

RIPPLE & NOISE (max.) Note.2

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

150mVp-p

200mVp-p

200mVp-p

VOLTAGE ADJ. RANGE

2.97 ~ 3.6V

3.6 ~ 4.4V

4.5 ~ 5.5V

10.2 ~ 13.8V

13.5 ~ 18V

21.6 ~ 28.8V

32.4 ~ 39.6V

43.2 ~ 52.8V

VOLTAGE TOLERANCE  Note.3

±4.0%

±4.0%

±3.0%

±1.5%

±1.0%

±1.0%

±1.0%

±1.0%

LINE REGULATION   Note.4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

LOAD REGULATION Note.5

±2.5%

±2.5%

±2.0%

±1.0%

±0.5%

±0.5%

±0.5%

±0.5%

SETUP, RISE TIME

1500ms, 50ms/230VAC         1500ms,50ms/115VAC  at full load

HOLD UP TIME (Typ.)

16ms/230VAC      12ms/115VAC at full load

INPUT

VOLTAGE RANGE

90 ~ 132VAC / 180 ~ 264VAC by switch          240 ~ 370VDC      (switch on 230VAC)

FREQUENCY RANGE

47 ~ 63Hz

EFFICIENCY (Typ.)

79.5%

81.5%

83.5%

85%

86%

88%

88.5%

89%

AC CURRENT (Typ.)

6.8A/115VAC        3.4A/230VAC

INRUSH CURRENT (Typ.)

60A/115VAC       60A/230VAC

LEAKAGE CURRENT

<2mA / 240VAC

PROTECTION

 

OVER LOAD

110 ~ 140% rated output power

3.3~36V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

 

OVER VOLTAGE

3.8 ~ 4.45V

4.6 ~ 5.4V

5.75 ~ 6.75V

13.8 ~ 16.2V

18 ~ 21V

28.8 ~ 33.6V

41.4 ~ 46.8V

55.2 ~ 64.8V

3.3~36V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

OVER TEMPERATURE

3.3~36V Hiccup mode, recovers automatically after fault condition is removed.

48V Shut down and latch off o/p voltage, re-power on to recover.

FUNCTION

FAN ON/OFF CONTROL (Typ.)

RTH3≥50℃ FAN ON, ≤40℃ FAN OFF

ENVIRONMENT

WORKING TEMP.

-25 ~ +70℃ (Refer to "Derating Curve")

WORKING HUMIDITY

20 ~ 90% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85℃, 10 ~ 95% RH

TEMP. COEFFICIENT

±0.03%/℃ (0 ~ 50℃)

VIBRATION

10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

OVER VOLTAGE CATEGORY

Ⅲ: According to EN61558, EN50178, EN60664-1, EN62477-1; altitude up to 2000 meters

SAFETY & EMC(Note9)

 

SAFETY STANDARDS

IEC/UL 62368-1,BSMI CNS15598-1,EAC TP TC 004,KC62368-1(for LRS-350-12/24 only),GB 4943.1, BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 12),BS EN/EN61558-1, BS EN61558-2-16

Designed by AS/NZS 61558. 1/2.16, AS/NZS 62368.1,BS EN/EN62368-1,

WITHSTAND VOLTAGE

I/P-O/P:3.75KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25℃/ 70% RH

EMC EMISSION

Compliance to BSMI CNS15936, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-350-12/24 only)

EMC IMMUNITY

Compliance to BS EN/EN55035, EAC TP TC 020,KS C 9832, KS C 9835(for LRS-350-12/24 only)

OTHERS

MTBF

2099.9K hrs min.      Telcordia SR-332 (Bellcore) ;   328.6Khrs min.      MIL-HDBK-217F (25℃)

DIMENSION

215* 115*30mm (L*W*H)

PACKING

0.76Kg; 15pcs/12.4Kg/0.67CUFT

NOTE

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0. 1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. Line regulation is measured from low line to high line at rated load.

5. Load regulation is measured from 0% to 100% rated load.

6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.

7. The 150% peak load capability is built in for up to 1 second for 12~48V.LRS-350 will enter hiccup mode if the peak load is delivered for over 1 second and will recover once it resumes to the rated current level(115VAC/230VAC).

8. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft).

9. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by

mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to“EMI testing of component power supplies.”

10. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions:

a) the end-devices is used within the European Union, and

b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and

c) the power supply is:

- installed in end-devices with average or continuous input power greater than 75W, or

- belong to part of a lighting system Exception:

Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2

a) professional equipment with a total rated input power greater than 1000W;

b) symmetrically controlled heating elements with a rated power less than or equal to 200W

11. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417. 1.

12. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.

Note:Inquiry for details.

Company Advantages

1.Refined Operations

A rigorous quality management system ensures products are delivered in one step, giving you a head start.

2.Strict Quality Inspection Process

Rapid production with guaranteed quality, creating reliable products for your peace of mind.

3.Comprehensive Warehouse Inventory

A complete range of product models for fast delivery.

4.Independent Innovation

The company boasts strong technical capabilities and prioritizes technological innovation.

Supplier Information

Company:eriksen

Email:halocore@ttbridge.com

Tel:13460222030

Recommended products

LRS Series Power Supply DC Converter–Industrial Switching Power Supply for LED & Automation

High-performance LRS power supply converts 220V AC to stable 24V/12V/5V DC for industrial and LED applications

collect:0