Product Description
The QT Series is a specialized multiple-output switching power supply designed to convert 220V AC input into stable 12V or 24V DC output across three or four independent channels. Available in various power configurations to suit different application requirements, it features compact metal housing, high efficiency, and comprehensive protections including overload, overvoltage, and short circuit protection. Ideal for commercial lighting, architectural illumination, and display applications where multiple independent circuits are needed.
Functional Features
Anti - interference Filter Comprehensive Protection Intelligent Chip
Copper Core Coil Transformer Large Capacity Electrolytic Capacitor Powerful Cooling System
Metal Mesh Heat Dissipation Design
More Efficient Heat Dissipation
The hollow honeycomb - shaped design dissipates heat faster and effectively protects the internal components of the switching power supply
Large Filter Capacitor
Full Copper Transformer
FILTER CAPACITOR
Large Filter Capacitor
High-temperature resistant electrolytic capacitor with strong environmental adaptability
TRANSFORMER
Full Copper Transformer
Made of pure copper with excellent electrical conductivity
Long service life
Product Views
Overload Protection
Overload protection within the range of 110% - 150%,
providing better self - defense.
Short - circuit Protection
Prevent the electrical equipment at the output terminal from causing electrical fires due to fault short - circuit.
Overvoltage Protection
Output overvoltage within the range of 110% - 140%,providing safety guarantee for downstream equipment.
Overtemperature Protection
Provide overtemperature protection for 200W and 350W high - power products.
AC: Alternating Current | DC: Direct Current |
+V: Connect to the positive pole of the device | COM: Connect to the negative pole of the device |
N: Connect to the neutral wire of the mains | L: Connect to the live wire of the mains |
ADJ: Output voltage adjustment | |
| Grounding symbol (earth ground) |
Safety Protection, Guarding at All Times
Good insulation, high electrical strength, soft - start current design
Effectively reduce the impact of AC input
Terminal Block
High - Quality Shell
Application
This product has a wide range of applications and is suitable for multiple industries. It can provide AC/DC power solutions for various industrial scenarios and is a product you can trust. In the field of industrial automation, it can serve as a DC power source for load devices such as PLCs, touch screens, controllers, and small relay coils; in the field of electronic information, it can be used for the DC power supply of load devices such as switches and touch screens; in the field of security monitoring, it can provide DC power for load devices such as cameras and fire protection modules; in the field of urban lighting, it can drive the DC power needs of load devices such as LED displays, light boxes, street lamps, and billboards.
Product parameters
Model | Rated Power | Output Voltage | Output Current | Product Dimensions |
T-30A | 30W | 5/12/-5V | 3/1/0.5A | 129*98*38mm |
T-30B | 30W | 5/12/-12V | 3/1/0.5A | 129*98*38mm |
T-30C | 30W | 5/15/-15V | 2/1/0.5A | 129*98*38mm |
T-30D | 30W | 5/12/-24V | 3/0.5/0.5A | 129*98*38mm |
T-50A | 50W | 5/12/-5V | 7/1/1A | 159*98*38mm |
T-50B | 50W | 5/12/-12V | 5/1/1A | 159*98*38mm |
T-50C | 50W | 5/15/-15V | 4/1/1A | 159*98*38mm |
T-50D | 50W | 5/12/24V | 3/1/1A | 159*98*38mm |
T-60A | 60W | 5/12/-5V | 5/2.5/0.5A | 159*98*38mm |
T-60B | 60W | 5/12/-12V | 5/2.5/0.5A | 159*98*38mm |
T-60C | 60W | 5/15/-15V | 5/2/0.5A | 159*98*38mm |
T-60D | 60W | 5/12/-24V | 5/2.5/0.5A | 159*98*38mm |
T-100A | 100W | 5/12/-5V | 10/4/1A | 199*110*50mm |
T-100B | 100W | 5/12/-12V | 10/3.5/1A | 199*110*50mm |
T-100C | 100W | 5/15/-15V | 10/2.5/1A | 199*110*50mm |
T-100D | 100W | 5/12/24V | 6/2/2A | 199*110*50mm |
T-120A | 120W | 5/12/-5V | 11/5/1A | 199*110*50mm |
T-120B | 120W | 5/12/-12V | 11/4.5/1A | 199*110*50mm |
T-120C | 120W | 5/15/-15V | 10/3.5/1A | 199*110*50mm |
T-120D | 120W | 5/12/24V | 8/2.5/2A | 199*110*50mm |
Model | Rated Power | Output Voltage | Output Current | Product Dimensions |
Q-60B | 60W | 5/12/-5/-12V | 5.5/2/0.5/0.5A | 159*98*38mm |
Q-60C | 60W | 5/15/-5/-15V | 5.5/1.5/0.5/0.5A | 159*98*38mm |
Q-60D | 60W | 5/12/24/-12V | 4A/1/1/0.5A | 159*98*38mm |
Q-75D | 75W | 5/12/24/-12V | 5/0.5/1.5/0.5A | 159*98*38mm |
Q-120B | 120W | 5/12/-5/-12V | 11/4/1/1A | 199*110*50mm |
Q-120C | 120W | 5/15/-5/-15V | 10/3.5/1/1A | 199*110*50mm |
Q-120D | 120W | 5/12/24/-12V | 8/2/2/1A | 199*110*50mm |
Q-150D | 150W | 5/12/24/-12V | 10/3/2.5/1A | 199*110*50mm |

T30 | ||||||||||||
Model | T-30A | T-30B | T-30C | T-30D | ||||||||
CH1 | CH2 | CH1 | CH1 | CH2 | CH2 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC Output Voltage | 5V | 12V | -5V | 5V | 12V | 12V | 5V | 15V | -15V | 5V | 12V | 24V |
Output Voltage Tolerance | ±2% | ±2%,-6% | ±2%,-10% | ±2% | ±2%,-10% | ±6% | ±2% | ±5% | ±5% | ±2% | ±2%,-6% | ±2% |
Rated Output Current | 3A | 1A | 0.5A | 3A | 1A | 0.5A | 3A | 0.5A | 0.5A | 3A | 0.5A | 0.5A |
Output Current Range | 0.5~3A | 0.1~1A | 0.1~0.5A | 1~3A | 0.1~0.1A | 0.1~0.5A | 0.5~3A | 0.1~0.5A | 0.1~0.5A | 0.5~3A | 0.1~1A | 0.1~1A |
Ripple & Noise (Note 3) | 50mVp-p | 100mVp-p | 50mVp-p | 50mVp-p | 50mVp-p | 100mVp-p | 50mVp-p | 100mVp-p | 100mVp-p | 50mVp-p | 100mVp-p | 100mVp-p |
Line Regulation (Note 4) | ±5% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% |
Load Regulation (Note 5) | ±5% | ±5% | ±5% | ±0.5% | ±5% | ±5% | ±0.5% | ±5% | ±5% | ±6% | ±0.5% | ±5% |
DC Output Power | 30W | 33W | ||||||||||
Efficiency | 70% | 73% | ||||||||||
DC Voltage Adjustable Range | CH1;+10,-5% | CH1;+10,-5% | ||||||||||
Input Voltage Range | 85~132VAC/170~264VAC selectable by switch, 47~63Hz; 240~370VDC | |||||||||||
Input Current | 0.8A at 115V, 0.45A at 230V | |||||||||||
Inrush Current | Inrush Current: 18A at 115V, 36A at 230V | |||||||||||
Leakage Current | <0.5mA at 240VAC | |||||||||||
Overload Protection | 105%~145%, Type: Output cut-off, Reset: Auto-recovery | |||||||||||
Overvoltage Protection | CH1: 5.75~6.75V | |||||||||||
Over-Temperature Protection | -10℃~+60℃, 20%~90%RH | |||||||||||
Temperature Coefficient | ±0.03%/℃ (0~50℃), ON-5V | |||||||||||
Start-up, Rise, Hold-up Time | 200ms, 100ms, 30ms | |||||||||||
Shock Resistance | 10~500Hz, 2G, 10min/cycle, total duration 60min, on each axis | |||||||||||
Withstand Voltage | Between input and output: 1.5kVAC; Between input and case: 1.5kVAC; Between output and case: 0.5kVAC | |||||||||||
Isolation Resistance | Between input and output: Between input and case: 500VDC/100MΩ | |||||||||||
Operating Temperature & Humidity | -10℃~+60℃ (refer to output characteristic diagram), 20%~90%RH | |||||||||||
Storage Temperature & Humidity | -20℃~+85℃,10%~95%RH | |||||||||||
Dimensions | 129*98*38mm | |||||||||||

T-50 | ||||||||||||
Model | T-50A | T-50B | T-50C | T-50D | ||||||||
CH1 | CH2 | CH1 | CH1 | CH2 | CH2 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC Output Voltage | 5V | 12V | -5V | 5V | 12V | 12V | 5V | 15V | -15V | 5V | 12V | 24V |
Output Voltage Tolerance | ±2% | ±2%;-6% | ±2%;-10% | ±2% | ±2%;-10% | ±6% | ±2% | ±5% | ±5% | ±2% | ±2%;-6% | ±2% |
Rated Output Current | 7A | 1A | 1A | 5A | 1A | 1A | 4A | 1A | 1A | 4A | 1A | 1A |
Output Current Range | 0.5~3A | 0.1~1A | 0.1~0.5A | 1~3A | 0.1~0.1A | 0.1~0.5A | 0.5~3A | 0.1~0.5A | 0.1~0.5A | 0.5~3A | 0.1~1A | 0.1~1A |
Ripple & Noise (Note 3) | 50mVp-p | 100mVp-p | 50mVp-p | 50mVp-p | 50mVp-p | 100mVp-p | 50mVp-p | 100mVp-p | 100mVp-p | 50mVp-p | 100mVp-p | 100mVp-p |
Line Regulation (Note 4) | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% |
Load Regulation (Note 5) | ±0.5% | ±5% | ±5% | ±0.5% | ±5% | ±5% | ±0.5% | ±5% | ±5% | ±6% | ±0.5% | ±5% |
DC Output Power | 52W | 49W | 50W | 56W | ||||||||
Efficiency | 66% | 69% | 71% | 72% | ||||||||
DC Voltage Adjustable Range | CH1;+10,-5% | CH1;+10,-5% | CH1;+10,-5% | CH1;+10,-5% | ||||||||
Input Voltage Range | 85~132VAC/170~264VAC selectable by switch 47~63Hz;240~370VDC | |||||||||||
Input Current | 0.8A/115V 0.45A/230V | |||||||||||
Inrush Current | Inrush Current 18A/115V 36A/230V | |||||||||||
Leakage Current | <0.5mA/240VAC | |||||||||||
Overload Protection | 105%~145%Type: Output cut-off, Reset: Auto-recovery | |||||||||||
Overvoltage Protection | CH1;5.75~6.75V | |||||||||||
Over-Temperature Protection | -10℃~+60℃,20%~90%RH | |||||||||||
Temperature Coefficient | ±0.03%℃/(0~50℃) ON-5V | |||||||||||
Start-up, Rise, Hold-up Time | 200ms 50ms 30ms | |||||||||||
Shock Resistance | 10~500Hz, 2G, 10min/cycle, total duration 60min, on each axis | |||||||||||
Withstand Voltage | Between input and output: 1.5kVAC; Between input and case: 1.5kVAC; Between output and case: 0.5kVAC | |||||||||||
Isolation Resistance | Between input and output: Between input and case: 500VDC/100MΩ | |||||||||||
Operating Temperature & Humidity | -10℃~+60℃ (refer to output characteristic diagram), 20%~90%RH | |||||||||||
Storage Temperature & Humidity | -20℃~+85℃,10%~95%RH | |||||||||||
Dimensions | 159*98*38mm | |||||||||||

T-60 | ||||||||||||
Model | T-60A | T-60B | T-60C | T-60D | ||||||||
CH1 | CH2 | CH1 | CH1 | CH2 | CH2 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC Output Voltage | 5V | 12V | -5V | 5V | 12V | 12V | 5V | 15V | -15V | 5V | 12V | 24V |
Output Voltage Tolerance | ±2% | ±2%,6% | ±2%,10% | ±2% | ±2%,10% | ±6% | ±2% | ±5% | ±5% | ±2% | ±2%,6% | ±2% |
Rated Output Current | 7A | 2A | 1A | 6A | 2A | 1A | 5A | 2A | 0.5A | 5A | 1A | 1A |
Output Current Range | 1~7A | 0.2~2A | 0.1~1A | 1~6A | 0.2~2A | 0.1~1A | 1~5A | 0.2~2A | 0.1~0.5A | 0.5~3A | 0.1~1A | 0.1~1A |
Ripple & Noise (Note 3) | 50mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Line Regulation (Note 4) | ±0.5% | ±1% | ±0.5% | ±0.5% | ±1% | ±0.5% | ±0.5% | ±1% | ±0.5% | ±0.5% | ±1% | ±0.5% |
Load Regulation (Note 5) | ±1% | ±4% | ±1% | ±1% | ±4% | ±5% | ±1% | ±4% | ±1% | ±1% | ±4% | ±1% |
DC Output Power | 64W | 65W | 62.9W | 63W | ||||||||
Efficiency | 72% | 72% | 72% | 72% | ||||||||
DC Voltage Adjustable Range | CH1;+10,-5% | CH1;+10,-5% | CH1;+10,-5% | CH1;+10,-5% | ||||||||
Input Voltage Range | 85~132VAC/170~264VAC selectable by switch 47~63Hz;240~370VDC | |||||||||||
Input Current | 0.8A/115V 0.45A/230V | |||||||||||
Inrush Current | Inrush Current 18A/115V 36A/230V | |||||||||||
Leakage Current | <0.5mA/240VAC | |||||||||||
Overload Protection | 105%~145% Type: Output cut-off, Reset: Auto-recovery | |||||||||||
Overvoltage Protection | CH1;5.75~6.75V | |||||||||||
Over-Temperature Protection | -10℃~+60℃,20%~90%RH | |||||||||||
Temperature Coefficient | ±0.03℃/(0~50℃) ON-5V | |||||||||||
Start-up, Rise, Hold-up Time | 200ms 50ms 30ms | |||||||||||
Shock Resistance | 10~500Hz, 2G, 10min/cycle, total duration 60min, on each axis | |||||||||||
Withstand Voltage | Between input and output: 1.5kVAC; Between input and case: 1.5kVAC; Between output and case: 0.5kVAC | |||||||||||
Isolation Resistance | Between input and output: Between input and case: 500VDC/100MΩ | |||||||||||
Operating Temperature & Humidity | -10℃~+60℃ (refer to output characteristic diagram), 20%~90%RH | |||||||||||
Storage Temperature & Humidity | -20℃~+85℃,10%~95%RH | |||||||||||
Dimensions | 159*98*38mm | |||||||||||

T-100 | ||||||||||||
Model | T-100A | T-100B | T-100C | T-100D | ||||||||
CH1 | CH2 | CH1 | CH1 | CH2 | CH2 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC Output Voltage | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 12V | 24V |
Output Voltage Tolerance | ±2% | ±6% | ±6% | ±2% | ±6% | ±6% | ±2% | ±5% | ±5% | ±2% | ±5% | ±5% |
Rated Output Current | 10A | 4A | 1A | 10A | 4A | 1A | 10A | 5A | 1A | 5A | 1A | 1A |
Output Current Range | 2~11A | 0.5~5A | 0.2~1A | 2~11A | 0.5~4.5A | 0.2~1A | 2~12A | 0.5~5A | 0.2~2A | 2~12A | 0.5~5A | 0.5~2A |
Ripple & Noise (Note 3) | 50mVp-p | 80mVp-p | 100mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 100mVp-p | 80mVp-p | 80mVp-p | 150mVp-p | 80mVp-p |
Line Regulation (Note 4) | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% |
Load Regulation (Note 5) | ±0.5% | ±5% | ±5% | ±6% | ±0.5% | ±5% | ±0.5% | ±0.5% | ±5% | ±0.5% | ±0.5% | ±0.5% |
DC Output Power | 102W | 102W | ||||||||||
Efficiency | 77% | 79% | ||||||||||
DC Voltage Adjustable Range | CH1;+10,-5% | CH1;+10,-5% | ||||||||||
Input Voltage Range | 85~132VAC/170~264VAC selectable by switch 47~63Hz;240~370VDC | |||||||||||
Input Current | 0.8A/115V 0.45A/230V | |||||||||||
Inrush Current | Inrush Current 18A/115V 36A/230V | |||||||||||
Leakage Current | <0.5mA/240VAC | |||||||||||
Overload Protection | 105%~145% Type: Output cut-off, Reset: Auto-recovery | |||||||||||
Overvoltage Protection | CH1;5.75~6.75V | |||||||||||
Over-Temperature Protection | -10℃~+60℃,20%~90%RH | |||||||||||
Temperature Coefficient | ±0.03℃/℃/(0~50℃) ON-5V | |||||||||||
Start-up, Rise, Hold-up Time | 200ms 50ms 30ms | |||||||||||
Shock Resistance | 10~500Hz, 2G, 10min/cycle, total duration 60min, on each axis | |||||||||||
Withstand Voltage | Between input and output: 1.5kVAC; Between input and case: 1.5kVAC; Between output and case: 0.5kVAC | |||||||||||
Isolation Resistance | Between input and output: Between input and case: 500VDC/100MΩ | |||||||||||
Operating Temperature & Humidity | -10℃~+60℃ (refer to output characteristic diagram), 20%~90%RH | |||||||||||
Storage Temperature & Humidity | -20℃~+85℃,10%~95%RH | |||||||||||
Dimensions | 199*110*50mm | |||||||||||

T-120 | ||||||||||||
Model | T-120A | T-120B | T-120C | T-120D | ||||||||
CH1 | CH2 | CH1 | CH1 | CH2 | CH2 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC Output Voltage | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 12V | 24V |
Output Voltage Tolerance | ±2% | ±6% | ±6% | ±2% | ±6% | ±6% | ±2% | ±5% | ±5% | ±2% | ±5% | ±5% |
Rated Output Current | 11A | 5A | 1A | 11A | 4.5A | 1A | 8A | 2.5A | 2A | 8A | 2.5A | 2A |
Output Current Range | 2~11A | 0.5~5A | 0.2~1A | 2~11A | 0.5~4.5A | 0.2~1A | 2~12A | 0.5~5A | 0.2~2A | 2~12A | 0.5~5A | 0.5~2A |
Ripple & Noise (Note 3) | 50mVp-p | 80mVp-p | 100mVp-p | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 100mVp-p | 80mVp-p | 80mVp-p | 150mVp-p | 80mVp-p |
Line Regulation (Note 4) | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% |
Load Regulation (Note 5) | ±0.5% | ±5% | ±5% | ±6% | ±0.5% | ±5% | ±0.5% | ±0.5% | ±5% | ±0.5% | ±0.5% | ±0.5% |
DC Output Power | 64W | 63W | ||||||||||
Efficiency | 72% | 72% | ||||||||||
DC Voltage Adjustable Range | CH1;+10,-5% | CH1;+10,-5% | ||||||||||
Input Voltage Range | 85~132VAC/170~264VAC selectable by switch 47~63Hz;240~370VDC | |||||||||||
Input Current | 0.8A/115V 0.45A/230V | |||||||||||
Inrush Current | Inrush Current 18A/115V 36A/230V | |||||||||||
Leakage Current | <0.5mA/240VAC | |||||||||||
Overload Protection | 105%~145% Type: Output cut-off, Reset: Auto-recovery | |||||||||||
Overvoltage Protection | CH1;5.75~6.75V | |||||||||||
Over-Temperature Protection | -10℃~+60℃,20%~90%RH | |||||||||||
Temperature Coefficient | ±0.03%℃/(0~50℃) ON-5V | |||||||||||
Start-up, Rise, Hold-up Time | 200ms 50ms 30ms | |||||||||||
Shock Resistance | 10~500Hz, 2G, 10min/cycle, total duration 60min, on each axis | |||||||||||
Withstand Voltage | Between input and output: 1.5kVAC; Between input and case: 1.5kVAC; Between output and case: 0.5kVAC | |||||||||||
Isolation Resistance | Between input and output: Between input and case: 500VDC/100MΩ | |||||||||||
Operating Temperature & Humidity | -10℃~+60℃ (refer to output characteristic diagram), 20%~90%RH | |||||||||||
Storage Temperature & Humidity | -20℃~+85℃,10%~95%RH | |||||||||||
Dimensions | 199*110*50mm | |||||||||||

Q-60 | ||||||
Model | Q-60B | Q-60D | ||||
CH1 | CH2 | CH2 | CH1 | CH2 | CH3 | |
DC Output Voltage | 5V | 12V | 12V | 5V | 12V | 24V |
Output Voltage Tolerance | ±2% | ±2%,-10% | ±6% | ±2% | ±2%,-6% | ±2% |
Rated Output Current | 6A | 2A | 1A | 5A | 1A | 1A |
Output Current Range | 1~6A | 0.2~2A | 0.1~1A | 0.5~3A | 0.1~1A | 0.1~1A |
Ripple & Noise (Note 3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Line Regulation (Note 4) | ±0.5% | ±1% | ±0.5% | ±0.5% | ±1% | ±0.5% |
Load Regulation (Note 5) | ±1% | ±4% | ±5% | ±1% | ±4% | ±1% |
DC Output Power | 65W | 63W | ||||
Efficiency | 72% | 72% | ||||
DC Voltage Adjustable Range | CH1;+10,-5% | CH1;+10,-5% | ||||
Input Voltage Range | 85~132VAC/170~264VAC selectable by switch 47~63Hz;240~370VDC | |||||
Input Current | 0.8A/115V 0.45A/230V | |||||
Inrush Current | Inrush Current 18A/115V 36A/230V | |||||
Leakage Current | <0.5mA/240VAC | |||||
Overload Protection | 105%~145% Type: Output cut-off, Reset: Auto-recovery | |||||
Overvoltage Protection | CH1;5.75~6.75V | |||||
Over-Temperature Protection | -10℃~+60℃,20%~90%RH | |||||
Temperature Coefficient | ±0.03℃/(0~50℃) ON-5V | |||||
Start-up, Rise, Hold-up Time | 200ms 50ms 30ms | |||||
Shock Resistance | 10~500Hz, 2G, 10min/cycle, total duration 60min, on each axis | |||||
Withstand Voltage | Between input and output: 1.5kVAC; Between input and case: 1.5kVAC; Between output and case: 0.5kVAC | |||||
Isolation Resistance | Between input and output: Between input and case: 500VDC/100MΩ | |||||
Operating Temperature & Humidity | -10℃~+60℃ (refer to output characteristic diagram), 20%~90%RH | |||||
Storage Temperature & Humidity | -20℃~+85℃,10%~95%RH | |||||
Dimensions | 159*98*38mm | |||||

Q-120 | ||||||||||||
Model | Q-120A | Q-120B | Q-120C | Q-120D | ||||||||
CH1 | CH2 | CH1 | CH1 | CH2 | CH2 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | |
DC Output Voltage | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | 5V | 12V | 24V |
Output Voltage Tolerance | ±2% | ±6% | ±6% | ±2% | ±6% | ±6% | ±2% | ±5% | ±5% | ±2% | ±5% | ±5% |
Rated Output Current | 11A | 5A | 1A | 11A | 4.5A | 1A | 8A | 2.5A | 2A | 8A | 2.5A | 2A |
Output Current Range | 2~11A | 0.5~5A | 0.2~1A | 2~11A | 0.5~4.5A | 0.2~1A | 2~12A | 0.5~5A | 0.2~2A | 2~12A | 0.5~5A | 0.5~2A |
Ripple & Noise (Note 3) | 50mVp-p | 90mVp-p | 100mVp-p | 90mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 100mVp-p | 80mVp-p | 90mVp-p | 150mVp-p | 90mVp-p |
Line Regulation (Note 4) | ±0.5% | ±1% | ±1% | ±1% | ±0.5% | ±1% | ±0.5% | ±1% | ±1% | ±0.5% | ±1% | ±1% |
Load Regulation (Note 5) | ±0.5% | ±5% | ±5% | ±6% | ±0.5% | ±5% | ±0.5% | ±0.5% | ±5% | ±0.5% | ±0.5% | ±0.5% |
DC Output Power | 64W | 63W | ||||||||||
Efficiency | 72% | 72% | ||||||||||
DC Voltage Adjustable Range | CH1;+10,-5% | CH1;+10,-5% | ||||||||||
Input Voltage Range | 85~132VAC/170~264VACselectable by switch 47~63Hz;240~370VDC | |||||||||||
Input Current | 0.8A/115V 0.45A/230V | |||||||||||
Inrush Current | Inrush Current 18A/115V 36A/230V | |||||||||||
Leakage Current | <0.5mA/240VAC | |||||||||||
Overload Protection | 105%~145% Type: Output cut-off, Reset: Auto-recovery | |||||||||||
Overvoltage Protection | CH1;5.75~6.75V | |||||||||||
Over-Temperature Protection | -10℃~+60℃,20%~90%RH | |||||||||||
Temperature Coefficient | ±0.03%℃/(0~50℃) ON-5V | |||||||||||
Start-up, Rise, Hold-up Time | 200ms 50ms 30ms | |||||||||||
Shock Resistance | 10~500Hz, 2G, 10min/cycle, total duration 60min, on each axis | |||||||||||
Withstand Voltage | Between input and output: 1.5kVAC; Between input and case: 1.5kVAC; Between output and case: 0.5kVAC | |||||||||||
Isolation Resistance | Between input and output: Between input and case: 500VDC/100MΩ | |||||||||||
Operating Temperature & Humidity | -10℃~+60℃ (refer to output characteristic diagram), 20%~90%RH | |||||||||||
Storage Temperature & Humidity | -20℃~+85℃,10%~95%RH | |||||||||||
Dimensions | 199*110*50mm | |||||||||||
Our Advantages
1.Refined Operations
A rigorous quality management system ensures products are delivered in one step, giving you a head start.
2.Strict Quality Inspection Process
Rapid production with guaranteed quality, creating reliable products for your peace of mind.
3.Comprehensive Warehouse Inventory
A complete range of product models for fast delivery.
4.Independent Innovation
The company boasts strong technical capabilities and prioritizes technological innovation.
Precautions
1.Select the appropriate power. To prolong the service life of the power supply, please choose a product with an output power rating 30% higher than that of the electrical appliance. For example, for an 80W electrical appliance, select a 100W power supply.
2.Since the switching power supply has high working efficiency (generally reaching more than 80%), when selecting the output current, the maximum current absorbed by the electrical equipment should be accurately measured or calculated. Generally, the one with a larger output current is the main output.
3.Before energizing, check whether the input and output leads are connected correctly to avoid damaging the equipment.
4.Multi - output power supplies are generally divided into main and auxiliary outputs. The characteristics of the main output are better than those of the auxiliary output. Generally, the one with a larger output current is the main output.
5.The power supply shall not be installed in an environment with flammable materials and materials that are easy to catch fire (such as wood products, plastics, cardboard and other flammable items) to prevent fire and fire accidents.