Product Description
Grid-Tied Solar Inverter delivers high efficiency, reliability, and intelligent performance across residential, commercial, and utility-scale PV applications. Featuring advanced topology and multi-MPPT design, it achieves maximum efficiency of over 99%, compatible with various high-performance PV modules to maximize energy yield. With IP66 protection rating and C5 anti-corrosion capability, it ensures stable operation even in harsh environments such as coastal areas, high humidity, and dusty conditions. Built-in safety features include AFCI (arc fault protection), AC/DC surge protection, and anti-islanding protection, safeguarding both the system and personnel. Multiple communication options including WiFi, 4G, and RS485 enable seamless integration with the iSolarCloud platform for remote monitoring, operation, and data analysis. From residential rooftops to large-scale power plants, Sungrow delivers a safe, efficient, and sustainable energy solution backed by global leadership in PV technology.
Functional Features
SG20-25T-P2-CN | SG30-33T-P2-CN | SG36/40CX-P3-CN | SG5OT-CN | SG5OCX-P3-CN |
High-efficiency Power Generation | ||||
Ultra-wide voltage range, adapts to complex grid conditions | ||||
Global MPPT scanning increases power generation by 2% | ||||
Safe & Worry-free | ||||
AC/DC dual-level lightning protection design, proactively eliminates lightning risks | ||||
IP66 protection + C5 corrosion resistance, withstands heat and resists corrosion | ||||
Flexible Design | ||||
Supports long/short string configurations, flexible DC connection design | ||||
20A high current, compatible with all types of PV modules | ||||
Convenient Operation & Maintenance | ||||
One-click scan, smart system setup | ||||
Intelligent cloud control, accessible with one touch | ||||
SG10-17T-CN
High conversion efficiency, wide operating voltage range, early startup and late shutdown for sustained performance
1100V max input voltage increases energy yield by approximately 2%; 20A current supports 182/210mm modules
AC/DC Type II surge protection and EMC filtering ensure equipment and household appliance safety
IP65 protection rating and C5 anti-corrosion capability for reliable operation in harsh environments
One-click QR code setup and mobile cloud monitoring for convenient O&M
Principle Description
The inverter principle design is shown in the following diagram.
Take SG10-17T-CN as an example
MPPT
(Circuit 1)
DC EMI Filter AC Filter AC Relay AC EMI Filter
MPPT
(Circuit 2)
DC Switch DC Surge Arrester DC Busbar Inverter Unit AC Surge Arrester
Installation Precautions
Selecting the Installation Location
1.Choosing the optimal installation location for the inverter plays a very important role in its safe operation, service life assurance, and performance guarantee.
2.The inverter has an IP65 protection rating and can be installed indoors or outdoors.
3.The installation location should facilitate electrical connections, operation, and maintenance.
Installation Environment Requirements
Installation Environment Requirements
1.If the inverter is installed in an area with lush vegetation, please perform regular weeding. Additionally, the ground beneath the inverter.
2.should be modified, such as by laying cement or gravel (the recommended area is 3m × 2.5m).
3.Do not install the inverter in environments that are flammable, explosive, or smoky.
4.It is strictly prohibited to install the inverter under air conditioning outlets, ventilation openings, cable exit windows of machine rooms, or other locations prone to water leakage, to prevent liquids from entering the equipment and causing malfunctions or short circuits.
5.The inverter must not be installed in areas containing corrosive substances, such as corrosive gases or organic solvents.

6.During operation, the surface of the inverter may have high temperatures and high voltages. Touching is strictly prohibited to prevent burns or electric shock.
7.The inverter must not be installed in locations where it can be easily touched by people.
8.It is very important to ensure good ventilation and heat dissipation for the inverter; please install it in a well-ventilated environment.
9.If the inverter is installed in a sealed or semi-sealed environment, additional cooling or ventilation devices must be added. The indoor ambient temperature during operation should not be higher than the outdoor temperature. A semi-sealed environment refers to a special space that is not fully enclosed on all six sides but is not conducive to natural ventilation, making it prone to gas accumulation or heat buildup.
10.The installation site must have solid ground without poor soil conditions such as clay, soft soil, or areas prone to subsidence. Low-lying areas prone to water accumulation or snow accumulation are strictly prohibited. The site’s horizontal plane should be above the historical highest water level of the region.
11.Installing the equipment in locations that can be flooded is strictly prohibited.
12.To avoid interference from ground vegetation or standing water affecting normal inverter operation, the bottom clearance can be appropriately raised if the top clearance meets requirements.
13.It is recommended to install the inverter in a shaded location to avoid direct sunlight or adverse weather (such as snow, rain, lightning, etc.). If installed in direct sunlight, the inverter has a self-protection derating function in high-temperature environments, which may lead to reduced power output as temperatures rise.
14.Before installing the inverter outdoors in a salt spray area, consult Sungrow Power Supply Co., Ltd. Salt spray areas mainly refer to coastal regions within 500 meters of the shore. The amount of salt spray deposition varies significantly depending on the characteristics of adjacent seawater, sea breeze, precipitation, air humidity, topography, and forest cover.
15.The inverter must not be installed in chemically polluted environments, such as those containing halogens or sulfides.
16.The inverter must not be installed in environments with vibration or strong electromagnetic fields (which may cause common-mode interference). A strong magnetic field environment refers to one where the magnetic field strength exceeds 30 A/m. Such environments may cause the machine to malfunction.
17.In dusty environments, such as areas with excessive dust, smoke, or fibrous materials, particles in the environment may accumulate at the equipment’s air outlet or heat sink, affecting heat dissipation and potentially damaging the machine during cleaning. Therefore, the inverter must not be installed in dusty environments. If unavoidable, regularly clean the fans and heat sinks to ensure a good heat dissipation environment.
18.To avoid noise from equipment operation disturbing residents in living areas, do not install the inverter in noise-sensitive areas such as bedrooms. Preferably choose open locations far from residential rest areas.
19.The working environment temperature is based on the average temperature within 1 meter around the inverter.mpe Terature and humidity should meet the following requirements:

Installation Support Requirements
Installation Support Requirements
The load-bearing capacity of the installation support must be at least 4 times the weight of the inverter and match its dimensions.
It is strictly prohibited to install the inverter on supports that may generate resonance, to prevent excessive noise.
Installing the inverter on flammable building materials is strictly prohibited. It can be installed on non-flammable walls (such as concrete, fire-rated plasterboard, brick walls, etc.) and roofs (such as color steel tiles, precast concrete slabs, fiber-reinforced cement boards, etc.).
Installation Angle
Requirements
Installation Angle Requirements
It is recommended to install the inverter vertically; do not install it tilted forward, backward, upside down, horizontally, or sideways.
Installation Space Requirements
Ensure sufficient space around the inverter to guarantee ventilation.
The required installation space for a single inverter is shown in the figure below.
When installing multiple inverters, a certain spacing should be reserved between them, and linear (single-row) installation is recommended.

Application
This link integrates a comprehensive selection of three-phase grid-tied PV inverters, including models such as SG10T-17T-CN,
SG20-25T-P2-CN,SG30-33T-P2-CN,SG36/40CX-P3-CN,SG5OT-CN,SG5OCX-P3-CN, covering a wide range of applications from small to medium commercial projects and large residential rooftop systems. With power ratings from 10kW to 36kW and support for high input current, these inverters are compatible with 182mm and 210mm high-efficiency PV modules to maximize energy yield. Multiple MPPT designs provide flexible adaptation to complex roof orientations, enhancing overall system efficiency. Featuring IP66 protection rating, these inverters are built to withstand harsh outdoor environments, with integrated safety protections including AFCI arc fault protection and AC/DC surge protection to ensure stable system operation. Multiple communication options such as RS485, WiFi, and 4G enable convenient remote monitoring and maintenance. Whether for commercial rooftops, schools, hospitals, or large residential applications, this series delivers a high-efficiency, reliable, and intelligent grid-tied solution.
Product parameters

Model | SG10T-CN | SG12T-CN | SG15T-CN | SG17T-CN | |
DC Input | |||||
Max Input Voltage | 1100 V | ||||
Min Input Voltage / Startup Voltage | 160 V / 180 V | ||||
Rated Input Voltage | 600V | ||||
MPPT Voltage Range | 160 V ~ 1000 V | ||||
Max Strings per MPPT | 1 / 1 | 2 / 1 | |||
Max Input Current per MPPT | 20 A / 20 A | 40 A / 20 A | |||
Max Total Input Current | 40 A(20 A / 20 A) | 60 A(40 A / 20 A) | |||
Number of MPPTs | 2 | ||||
Max Terminal Current (DC Input) | 25 A | ||||
Max DC Short-Circuit Current | 50 A(25 A / 25 A) | 75 A(50 A / 25 A) | |||
AC Output | |||||
Rated Output Power | 10000 W | 12000 W | 15000 W | 17000 W | |
Max Output Power | 11000 W | 13200 W | 16500 W | 18700 W | |
Max Output Apparent Power | 11000 VA | 13200 VA | 16500 VA | 18700 VA | |
Max Output Current | 16.7 A | 20.0 A | 25.0 A | 28.3 A | |
Rated Grid Voltage | 3 / N / PE,230 V / 400 V,220 V / 380 V | ||||
Grid Voltage Range | 156 V ~ 300 V(Phase Voltage) | ||||
Rated Grid Frequency / Grid Frequency Range | 50 Hz / 45 Hz ~ 55 Hz | ||||
Total Harmonic Distortion (THD) | <3 %(at Rated Power) | ||||
DC Current Injection | <0.5 % In | ||||
Power Factor | >0.99(at Rated Power) | ||||
Adjustable Power Factor Range | 0.8 Leading ~ 0.8 Lagging | ||||
Output Phases | 3 / 3 - N - PE | ||||
Efficiency | |||||
Peak Efficiency | 98.2 % | 98.3 % | |||
European Efficiency | 97.8 % | 98.0 % | 98.1 % | ||
Protection & Features | |||||
DC Reverse Polarity Protection | Available | ||||
AC Short-Circuit Protection | Available | ||||
Leakage Protection | Available | ||||
Grid Monitoring | Available | ||||
DC Switch | Available | ||||
String Detection | Available | ||||
Anti-Islanding Protection | Available | ||||
Surge Protection | DC Level II / AC Level II | ||||
General Specifications | |||||
Dimensions | 410 mm * 530 mm * 208 mm | ||||
Weight | 18 kg | 21 kg | |||
Isolation Method | Without Transformer | ||||
IP Rating | IP65 | ||||
Nighttime Losses | ≤1 W | ||||
Operating Temperature Range | -25℃~+60℃ | ||||
Operating Humidity Range | 0%~100%(Non-condensing) | ||||
Cooling Method | Natural Convection | Smart Forced Air Cooling | |||
Max Operating Altitude | 4000 m(Derating above 2000 m) | ||||
Display | LED,APP | ||||
Communication | 4G + RS485 * 1 | ||||
DC Connector Type | MC4Compatible Terminals | ||||
AC Connector Type | OT / DT Terminals | ||||
Compliance Standards | NB/T 32004-2018 | ||||
GB/T 37408-2019 | |||||
Grid Support | Anti-islanding, Active/Reactive Power Regulation, PF Control, Soft Start/Shutdown | ||||

Model | SG20T-P2-CN | SG2ST-P2-CN | SG25T-P2-CN |
DC Input | |||
Max Input Voltage | 1100 V | ||
Min Input Voltage / Startup Voltage | 160 V / 180 V | ||
Rated Input Voltage | 680V | ||
MPPT Voltage Range | 160 V – 1000 V | ||
Max Strings per MPPT | 2 / 2 | ||
Max Input Current per MPPT | 40 A / 40 A | ||
Max Input Current | 80 A(40 A / 40 A) | ||
Number of MPPTs | 2 | ||
Max Terminal Current (DC Input) | 25 A | ||
Max DC Short-Circuit Current | 100 A(50 A / 50 A) | ||
AC Output | |||
Rated Output Power | 20000 W | 23000 W | 25000 W |
Max Output Power | 22000 W | 25300 W | 27500 W |
Max Output Apparent Power | 22000 VA | 25300 VA | 27500 VA |
Max Output Current | 33.3 A | 38.3 A | 41.7 A |
Rated Grid Voltage | 3 / N / PE,230 V / 400 V,220 V / 380 V | ||
Grid Voltage Range | 156 V – 300 V(Phase Voltage) | ||
Rated Grid Frequency / Grid Frequency Range | 50 Hz / 45 Hz – 55 Hz | ||
Total Harmonic Distortion (THD) | <3 %(at Rated Power) | ||
DC Current Injection | <0.5 % In | ||
Power Factor | >0.99(at Rated Power) | ||
Adjustable Power Factor Range | 0.8 Leading ~ 0.8 Lagging | ||
Output Phases | 3 / 3 - N - PE | ||
Efficiency | |||
Max Efficiency | 98.5 % | 98.6 % | |
European Efficiency | 98.3 % | ||
Protection & Features | |||
DC Short-Circuit Protection | Available | ||
AC Short-Circuit Protection | Available | ||
Residual Current Protection (RCD) | Available | ||
Grid Monitoring | Available | ||
DC Switch | Available | ||
String Monitoring | Available | ||
Anti-Islanding Protection | Available | ||
Surge Protection | DC Level II / AC Level II | ||
General Parameters | |||
Dimensions | 510 mm * 420 mm * 226 mm | ||
Weight | 19 kg | ||
Isolation Type | Without Transformer | ||
Ingress Protection (IP) Rating | IP66 | ||
Nighttime Consumption | <1 W | ||
Operating Temperature Range | -25 ℃ – 60 ℃ | ||
Operating Humidity Range (Non-condensing) | 0 % – 100 % | ||
Cooling Method | Smart Forced Air Cooling | ||
Max Operating Altitude | 4000 m(Derating above 2000 m) | ||
Noise | <50 dB | ||
Display | LED,APP | ||
Communication | 4G + RS485 * 1 | ||
DC Terminal Type | MC4Compatible Terminals | ||
AC Terminal Type | OT Tighten the screws | ||
Compliance Standards | NBT 32004-2018 | ||
GB/T 37408-2019 | |||
Grid Support | Anti-islanding | ||

Model | SG30T-P2-CN | SG33T-P2-CN |
DC Input | ||
Max Input Voltage | 1100 V | |
Min Input Voltage / Startup Voltage | 160 V / 180 V | |
Rated Input Voltage | 680 V | |
MPPT Voltage Range | 160 V - 1000 V | |
Max Strings per MPPT | 272 / 1 | |
Max Input Current per MPPT | 40 A / 40 A / 20 A | |
Max Total Input Current | 100 A (40 A / 40 A / 20 A) | |
Number of MPPTs | 3 | |
Max Terminal Current (DC Input) | 25 A | |
Max Input Short-Circuit Current | 125 A (50 A / 50 A / 25 A) | |
AC Output | ||
Rated Output Power | 30000 W | 33000 W |
Max Output Power | 33000 W | 36300 W |
Max Output Apparent Power | 33000 VA | 36300 VA |
Max Output Current | 50.0 A | 55.0 A |
Rated Grid Voltage | 3 / N / PE,230 V / 400 V,220 V / 380 V | |
Grid Voltage Range | 156 V ~ 300 V (Phase Voltage) | |
Rated Frequency / Grid Frequency Range | 50 Hz / 45 Hz ~ 55 Hz | |
Total Harmonic Distortion (THD) | <3% (at Rated Power) | |
DC Injection | <0.5% In | |
Power Factor | 0.99 (at Rated Power) | |
Adjustable Power Factor Range | 0.8 Leading ~ 0.8 Lagging | |
Feeding Phases / Output Phases | 3 / 3 - N - PE | |
Efficiency | ||
Peak Efficiency | 98.6 % | |
European Efficiency | 98.3 % | |
Protection & Features | ||
DC Reverse Polarity Protection | Available | |
AC Short-Circuit Protection | Available | |
Residual Current Protection | Available | |
Grid Monitoring | Available | |
DC Switch | Available | |
String Monitoring | Available | |
Anti-Islanding Protection | Available | |
Surge Protection | DC Level II / AC Level II | |
General Parameters | ||
Dimensions | 615 mm * 466 mm * 225 mm | |
Weight | 25 kg | |
Isolation Type | Without Transformer | |
Protection Rating (IP) | IP66 | |
Nighttime Consumption | <1 W | |
Operating Temperature Range | -25 ℃ – 60 ℃ | |
Operating Humidity Range (Non-condensing) | 0 % – 100 % | |
Cooling Method | Smart Forced Air Cooling | |
Max Operating Altitude | 4000 m(Derating above 2000 m) | |
Noise | <55 dB | |
Display | LED,APP | |
Communication | 4G + RS485 * 1 | |
DC Terminal Type | MC4Compatible Terminals | |
AC Terminal Type | OT Tighten the screws | |
Compliance Standards | NBT 32004-2018 | |
Compliance Standards | GB/T 37408-2019 | |
Grid Support | Anti-islanding | |

Model | SG36CX-P3-CN | SG40CX-P3-CN |
DC Input | ||
Max Input Voltage | 1100 V | |
Min Input Voltage / Startup Voltage | 160 V / 200 V | |
Rated Input Voltage | 600 V | |
MPPT Voltage Range | 160 V - 1000 V | |
Max Strings per MPPT | 2 / 2 / 2 / 1 | |
Max Input Current per MPPT | 40 A / 40 A / 32 A / 20 A | |
Max Total Input Current | 132 A(40 A / 40 A / 32 A / 20 A) | |
Number of MPPTs | 4 | |
Max Terminal Current (DC Input) | 30 A | |
Max DC Short-Circuit Current | 165 A(50 A / 50 A / 40 A / 25 A) | |
AC Output | ||
Rated Output Power | 36000 W | 40000 W |
Max Output Power | 39600 W | 44000 W |
Max Output Apparent Power | 39600 VA | 44000 VA |
Max Output Current | 60.2 A | 66.9 A |
Rated Grid Voltage | 3 / N / PE,220 V / 380V | |
Grid Voltage Range | 156 V – 300 V(Phase Voltage) | |
Rated AC Frequency / Grid Frequency Range | 50 Hz | |
Total AC Harmonic Distortion Rate | ≤ 3 %(at Rated Power) | |
DC Component | <0.5% In | |
Power Factor | >0.99(at Rated Power) | |
Adjustable Power Factor Range | 0.8 Leading ~ 0.8 Lagging | |
Feeding Phases / Output Phases | 3 / 3 N - PE | |
Efficiency | ||
Max Efficiency | 98.6 % | |
China Efficiency | 98.2 % | |
Protection | ||
DC Reverse Polarity Protection | Available | |
AC Short-Circuit Protection | Available | |
Leakage Current Protection | Available | |
Grid Monitoring | Available | |
DC Switch | Available | |
String Detection | Available | |
Anti-Islanding Protection | Available | |
Surge Protection | DC Level II / AC Level II | |
General Parameters | ||
Dimensions | 645 mm * 595 mm * 245 mm | |
Weight | 40 kg | |
Isolation Method | Non-Isolated | |
Protection Level | IP66 | |
Nighttime Loss | <1 W | |
Operating Temperature Range | -30 ℃ ~ +60 ℃ | |
Operating Humidity Range (No Condensation) | 0 % ~ 100 % | |
Cooling Method | Smart Forced Air Cooling | |
Max Operating Altitude | 4000 m(Derating above 2000 m) | |
Noise | ≤60 dB | |
Display | LED,APP | |
Communication | 4G+RS485 | |
DC Terminal Type | MC4Compatible Terminals | |
AC Terminal Type | OT Tighten the screws | |
Compliance Standards | NBT 32004-2018 GB/T 37408-2019 | |
Grid Support | Anti-islanding | |

Model | SC50T-CN |
DC Input | |
Max Input Voltage | 1100 V |
Min Input Voltage / Startup Voltage | 160 V / 200 V |
Rated Input Voltage | 600 V |
MPPT Voltage Range | 160 V - 1000 V |
Max Strings per MPPT | 2 / 2 / 2 / 2 |
Max Input Current per MPPT | 40 A / 40 A / 32 A / 32 A |
Max Total Input Current | 144 A(40 A / 40 A / 32 A / 32 A) |
Number of MPPTs | 4 |
Max Terminal Current (DC Input) | 30 A |
Max Short-Circuit Current | 180 A(50 A / 50 A / 40 A / 40 A) |
AC Output | |
Rated Output Power | 50000 W |
Max Output Power | 55000 W |
Max Output Apparent Power | 55000 VA |
Max Output Current | 83.6 A |
Rated Grid Voltage | 3 / N / PE,230 V / 400 V,220 V / 380 V |
Grid Voltage Range | 156 V - 300 V (Phase Voltage) |
Rated Grid Frequency / Grid Frequency Range | 50 Hz / 45 Hz ~ 55 Hz |
Total Current Distortion Factor | <3% (at Rated Power) |
DC Component | <0.5% In |
Power Factor | 0.99 (at Rated Power) |
Adjustable Power Factor Range | 0.8 Leading - 0.8 Lagging |
Feeding Capability / Output Phases | 3 / 3+N-PE |
Efficiency | |
Max Efficiency | 98.60% |
China Efficiency | 98.20% |
Protection | |
DC Reverse Polarity Protection | Available |
AC Short-Circuit Protection | Available |
Leakage Current Protection | Available |
Grid Monitoring | Available |
DC Switch | Available |
String Detection | Available |
Anti-Islanding Protection | Available |
Surge Protection | DC Level II / AC Level II |
General Parameters | |
Dimensions | 645 mm * 595 mm * 245 mm |
Weight | 40 kg |
Isolation Method | Transformerless |
Protection Rating | IP66 |
Nighttime Consumption | ≤1 W |
Operating Temperature Range | -25 ℃ - 60 ℃ |
Operating Humidity Range (No Condensation) | 0% - 100% (No Condensation) |
Cooling Method | Intelligent Forced Air Cooling |
Max Operating Altitude | 4000 m (Derating above 2000m) |
Noise | <50 dB |
Display | LED, APP |
Communication | 4G+RS485 * 1 |
DC Terminal Type | MCA Stranded Copper Terminal |
AC Terminal Type | OT Terminal |
Compliance Standards | NB/T 32004-2018/GB/T 37408-2019 |
Grid Support | Anti-Islanding, Remote Grid Recorder |

Model | SG50CX-P3-CN |
DC Input | |
Maximum Input Voltage | 1100 V |
Minimum Input Voltage / Startup Voltage | 160 V / 200 V |
Rated Input Voltage | 600 V |
MPPT Voltage Range | 160 V - 1000 V |
Maximum Strings per MPPT | 2 / 2 / 2 / 2 |
Maximum Input Current per MPPT | 40 A / 40 A / 32 A / 32 A |
Maximum Input Current | 144 A(40 A / 40 A / 32 A / 32 A) |
Number of MPPTs | 4 |
Maximum Port Current (DC Input) | 30 A |
Maximum DC Short-Circuit Current | 180 A(50 A / 50 A / 40 A / 40 A) |
AC Output | |
Rated Output Power | 50000 W |
Maximum Output Power | 55000 W |
Maximum Output Apparent Power | 55000 VA |
Maximum Output Current | 83.6 A |
Rated Grid Voltage | 3 / N / PE,220 V / 380 V |
Grid Voltage Range | 156 V - 300 V (Phase Voltage) |
Rated Grid Frequency / Grid Frequency Range | 50 Hz |
Total Harmonic Distortion | ≤3% (at Rated Power) |
DC Injection | <0.5% In |
Power Factor | 0.99 (at Rated Power) |
Adjustable Power Factor Range | 0.8 Leading - 0.8 Lagging |
Feeding Phases / Output Phases | 3 / 3+N+PE |
Efficiency | |
Maximum Efficiency | 98.6 % |
China Efficiency | 98.2 % |
Protection | |
DC Reverse Polarity Protection | Available |
AC Short-Circuit Protection | Available |
Leakage Current Protection | Available |
Grid Monitoring | Available |
DC Switch | Available |
String Detection | Available |
Anti-Islanding Protection | Available |
Surge Protection | DC Level I / AC Level II |
General Parameters | |
Dimensions | 645 mm * 595 mm * 245 mm |
Weight | 40 kg |
Isolation Method | Non-isolated |
Protection Rating | IP66 |
Nighttime Loss | <1 W |
Operating Temperature Range | -30 ℃ - 60 ℃ |
Operating Humidity Range (Non-Condensing) | 0 % - 100 % |
Cooling Method | Intelligent Cooling |
Maximum Operating Altitude | 4000 m (Derating above 2000m) |
Noise | ≤60 dB |
Display | LED, APP |
Communication | 4G+RS485 |
DC Terminal Type | MC4 Compatible Terminals |
AC Terminal Type | OT / DT Terminals |
Compliance Standards | NB/T 32004-2018 / GB/T 37408-2019 |
Grid Support | Anti-Islanding |
Note:Any question,please feel free to contact us.
Company Information
HaloCore Control has a complete R&D, production, and testing system. All products are independently developed and manufactured by us.Specialization, Integrity, Innovation, and Agility are our corporate values: stability, high efficiency, safety, full power output, multiple protection functions, with product reliability as our primary goal.
Specialization: Focused on power supplies and solutions, with extensive experience and rich case histories
Integrity: Honest and practical cooperation
Innovation: Smart innovation, leading technology development
Agility: Quick market response and rapid service
We strictly control and manage the entire development and production process in accordance with the ISO9001 quality system standards. Our products have passed international CE and RoHS certifications.