HaloCore Control
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems
  • Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems

Military-Grade Wide Input to Single Output DC-DC Converter Power Module for Industrial & Railway Systems

Military-grade isolated DC-DC converter power module with wide input range, 20W to 75W, and single regulated output for demanding applications.

Combination:
Output Power:20W;Input Voltage:12Vdc(9-18);Output Voltage:5V
Output Power:20W;Input Voltage:12Vdc(9-18);Output Voltage:12V
Output Power:20W;Input Voltage:12Vdc(9-18);Output Voltage:15V
Output Power:20W;Input Voltage:12Vdc(9-18);Output Voltage:24V
Output Power:20W;Input Voltage:12Vdc(9-18);Output Voltage:28V
Output Power:20W;Input Voltage:12Vdc(9-18);Output Voltage:48V
Output Power:20W;Input Voltage:12Vdc(9-18);Output Voltage Customized
Output Power:20W;Input Voltage:12Vdc(9-18);Output Voltage:19V
Output Power:20W;Input Voltage:24Vdc(18-36);Output Voltage:5V
Output Power:20W;Input Voltage:24Vdc(18-36);Output Voltage:12V
Output Power:20W;Input Voltage:24Vdc(18-36);Output Voltage:15V
Output Power:20W;Input Voltage:24Vdc(18-36);Output Voltage:24V
Output Power:20W;Input Voltage:24Vdc(18-36);Output Voltage:28V
Output Power:20W;Input Voltage:24Vdc(18-36);Output Voltage:48V
Output Power:20W;Input Voltage:24Vdc(18-36);Output Voltage Customized
Output Power:20W;Input Voltage:24Vdc(18-36);Output Voltage:19V
Output Power:20W;Input Voltage:48Vdc(36-72);Output Voltage:5V
Output Power:20W;Input Voltage:48Vdc(36-72);Output Voltage:12V
Output Power:20W;Input Voltage:48Vdc(36-72);Output Voltage:15V
Output Power:20W;Input Voltage:48Vdc(36-72);Output Voltage:24V
Output Power:20W;Input Voltage:48Vdc(36-72);Output Voltage:28V
Output Power:20W;Input Voltage:48Vdc(36-72);Output Voltage:48V
Output Power:20W;Input Voltage:48Vdc(36-72);Output Voltage Customized
Output Power:20W;Input Voltage:48Vdc(36-72);Output Voltage:19V
Output Power:20W;Input Voltage:100Vdc(60-160);Output Voltage:5V
Output Power:20W;Input Voltage:100Vdc(60-160);Output Voltage:12V
Output Power:20W;Input Voltage:100Vdc(60-160);Output Voltage:15V
Output Power:20W;Input Voltage:100Vdc(60-160);Output Voltage:24V
Output Power:20W;Input Voltage:100Vdc(60-160);Output Voltage:28V
Output Power:20W;Input Voltage:100Vdc(60-160);Output Voltage Customized
Output Power:20W;Input Voltage:100Vdc(60-160);Output Voltage:19V
Output Power:20W;Input Voltage:18Vdc(9-36);Output Voltage:5V
Output Power:20W;Input Voltage:18Vdc(9-36);Output Voltage:12V
Output Power:20W;Input Voltage:18Vdc(9-36);Output Voltage:15V
Output Power:20W;Input Voltage:18Vdc(9-36);Output Voltage:24V
Output Power:20W;Input Voltage:18Vdc(9-36);Output Voltage:28V
Output Power:20W;Input Voltage:18Vdc(9-36);Output Voltage Customized
Output Power:20W;Input Voltage:18Vdc(9-36);Output Voltage:19V
Output Power:20W;Input Voltage:36Vdc(18-75);Output Voltage:5V
Output Power:20W;Input Voltage:36Vdc(18-75);Output Voltage:12V
Output Power:20W;Input Voltage:36Vdc(18-75);Output Voltage:15V
Output Power:20W;Input Voltage:36Vdc(18-75);Output Voltage:24V
Output Power:20W;Input Voltage:36Vdc(18-75);Output Voltage:28V
Output Power:20W;Input Voltage:36Vdc(18-75);Output Voltage Customized
Output Power:20W;Input Voltage:36Vdc(18-75);Output Voltage:19V

USD 22-172

output value: Monthly Output500

contact shop

Product Description



HC:HaloCore Control

D: DC/DC Power Supply

XX: Output Power

XX: Input Voltage (9–18) (18–36) (24V (36–72) 48V (60–160) 18V (9–36) 36V (18–75))

S:Single Output ,D:Dual Output with Common Ground

XX:Output Voltage

H:H Package

J:Military Grade



HC:HaloCore Control

D: DC/DC Power Supply

XX: Output Power

XX: Input Voltage (9–18) (18–36) (24V (36–72) 48V (60–160) 18V (9–36) 36V (18–75))

S:Single Output ,D:Dual Output with Common Ground

XX:Output Voltage

H:H Package

Functional Features

  • Maximum 75W power output

  • Wide voltage input, high efficiency

  • Long - term short - circuit protection, self - recovery

  • Miniaturized package, high reliability, high isolation and pressure resistance

  • Metal shell, easy to install (terminal block wiring method)

  • Silicone gel potting, dustproof, moisture - proof, anti - oxidation

  • Applicable to industries such as railway, electric power, industrial control, instrumentation, measurement and control, UAV (Unmanned Aerial Vehicle), etc.

Sequence Number

Terminal Marking

Terminal Purpose

1

NC

No Connection (NC)

2

+Vin

Input Positive (+Vin)

3

-Vin

Input Negative (-Vin)

4

CNT

Control (Remote) (Refer to Manual for Usage)

5

NC

No Connection (NC)

6

+Vo

Output Positive (+Vout)

7

-Vo

Output Negative (-Vout)

8

TRIM

Output Trim/Adjust (Refer to Manual for Usage)

Instructions

This series of power supplies has no reverse input polarity protection; please verify correct polarity of input connections before powering on.

Note:Any question,please feel free to contact us.

Application

Module power supplies are widely used in various sectors of social production and daily life, including aerospace, rail vehicles, ships, military weapons, power generation and distribution, postal and telecommunications, metallurgy and mining, automatic control, household appliances, instrumentation, and scientific research experiments. They play an irreplaceable and vital role, particularly in high-reliability and high-technology fields.

Dimensional Drawin

Advantages of Power Module

● Simple Design

A power supply can be realized with just one power module and a few discrete components.

● Shortened Development Cycle

Module power supplies generally offer a variety of input and output options. Users can also stack or cross-connect modules to build modular combined power supplies, achieving multiple inputs and outputs, which significantly reduces prototype development time.

● Flexible Modification

If product design changes are required, simply replace or parallel another suitable power module.

● Low Technical Requirements

Module power supplies typically feature standardized front ends, highly integrated power modules, and other components, making power supply design simpler.

● Good Heat Dissipation

The housing of module power supplies integrates heat sink, radiator, and casing into one structure, enabling conduction cooling and keeping the power supply temperature close to the minimum. At the same time, it gives the module power supply an attractive appearance.

● High Quality and Reliability

Module power supplies are generally produced with fully automated manufacturing and high-tech production techniques, ensuring stable and reliable quality.

● Wide Range of Applications

Module power supplies can be widely used in various fields of social production and daily life, including aerospace, locomotives and ships, military weapons, power generation and distribution, postal and telecommunications, mining and metallurgy, automatic control, household appliances, instrumentation, and scientific research experiments. They play an irreplaceable and important role especially in high-reliability and high-technology fields.











                                                                                              Top View

1.Note: The definition of terminals is subject to the actual product.

2.The power supply shell must be tightly attached to the equipment shell to ensure effective heat dissipation. Otherwise, excessive temperature rise of the power supply will lead to power supply damage.

3.Please use a torque wrench when assembling the line clip to prevent the connecting terminal from stripping.

4.Terminal maximum current: 2A; Connector torque: M3 screw, 0.5N·m

Company Information

HaloCore Control has a complete R&D, production, and testing system. All products are independently developed and manufactured by us.Specialization, Integrity, Innovation, and Agility are our corporate values: stability, high efficiency, safety, full power output, multiple protection functions, with product reliability as our primary goal.

Specialization: Focused on power supplies and solutions, with extensive experience and rich case histories

Integrity: Honest and practical cooperation

Innovation: Smart innovation, leading technology development

Agility: Quick market response and rapid service

We strictly control and manage the entire development and production process in accordance with the ISO9001 quality system standards. Our products have passed international CE and RoHS certifications.

Product parameters

Common Model Selection Table

Model

Input Voltage

Output Voltage (Vdc)

Output Current (A)

Typical Efficiency

HCD30-XXS5H

12V(9-18)
24V(18-36)
48V(36-72)
18V(9-36)
36V(18-75)
100V(60-160)

5V

6A

85%

HCD30-XXS12H

12V

2.5A

86%

HCD30-XXS15H

15V

2A

86%

HCD30-XXS19H

19V

1.5A

86%

HCD30-XXS24H

24V

1.2A

86%

HCD30-XXS28H

28V

1A

86%

HCD30-XXS48H

48V

0.6A

86%

HCD50-XXS5H

5V

10A

85%

HCD50-XXS12H

12V

4.1A

86%

HCD50-XXS15H

15V

3.3A

86%

HCD50-XXS19H

19V

2.6A

86%

HCD50-XXS24H

24V

2.1A

86%

HCD50-XXS28H

28V

1.7A

86%

HCD50-XXS48H

48V

1A

86%

HCD60-XXS12H

12V(9-18)
24V(18-36)
48V(36-72)
100V(60-160)

12V

5A

86%

HCD60-XXS15H

15V

4A

86%

HCD60-XXS19H

19V

3.1A

86%

HCD60-XXS24H

24V

2.5A

86%

HCD60-XXS28H

28V

2.1A

86%

HCD60-XXS36H

36V

1.6A

86%

HCD60-XXS48H

48V

1.2A

86%

HCD75-XXS12H

12V

6.2A

86%

HCD75-XXS15H

15V

5A

86%

HCD75-XXS19H

19V

3.9A

86%

HCD75-XXS24H

24V

3.1A

86%

HCD75-XXS28H

28V

2.6A

86%

HCD75-XXS36H

36V

2A

86%

HCD75-XXS48H

48V

1.5A

86%

Power Derating Curve

Output Power Percentage(%)/Operating Case Temperature(℃)

1.Due to limited space, only some common models are listed here. Parameters can also be customized. For details, please consult customer service or sales staff.

2.It is generally recommended that the long - term power does not exceed 70% - 80% of the rated power, which will ensure a better service life.

3.Good ventilation is required. If the ventilation is poor or in a closed environment, a larger heat dissipation margin or derating operation is needed.

4.The terminal power supply must be installed close to the metal shell of the equipment to expand the heat dissipation area.

5.Please comprehensively consider the power selection of the power supply and leave sufficient margin. If it is an inductive load or a capacitive load, please confirm the maximum current.

Electrical Specifications

Input Characteristics

Min

Type

Max

Notes

Input Voltage Range

9V

12V

18V


18V

24V

36V


36V

48V

72V


60V

100V

160V


9V

18V

36V


18

36V

72V


Start-up Time


10ms

200ms

Nominal Input and Constant Resistance Load

Input Undervoltage Protection

0.5


3

Compared to Minimum Input Voltage, Nominal Load

CNT Remote Terminal

Turn-on

CNT Pin Floating / or Remote High Level (with respect to Vin-)

3.5Vdc(Min)~30Vdc(Max)

Turn-off

CNT Connected to GND / or Low Level (with respect to Vin-)

0Vdc(Min)~1.5Vdc(Max)

Input Standby Power

0.2W


1W

Input full range, output no load

Enclosure Material

Metal shielded enclosure

Input Surge Voltage

1.3 times the maximum input voltage

Hot Plug

Not supported

Input Filter

π-type filter


Output Characteristics

Min

Type

Max

Notes

Output Voltage Accuracy


±1%

±3%


Load Effect


±0.5%

±1.5%


Source Effect


±0.5%

±1%


Dynamic Response



4%Vo Pk deviation 400μS settling time

50~75% load, 50~25% load

Temperature Coefficient


±0.5%/°C


Maximum Value


Output Characteristics

Min

Type

Max

Notes

Output Overcurrent Protection

110%

140%

180%

Input full range, output rated power

Short-Circuit Protection

Long-term short-circuit protection, self-recovery

Output Regulation

±10%(input full range, %Vo)

Ripple & Noise

1% (typical value, by clamp-on measurement)

20MHz bandwidth

Peak-to-peak


General

Min

Type

Max

Notes

Isolation Voltage

1500VDC



Vout-case:500Vdc/min

Switching Frequency


300KHz



Mean Time Between Failures


2×105Hrs


Mil HDBK 217F Tc=25℃

Operating Temperature

-25℃


+55℃

Industrial Grade: -25℃ ~ +55℃
Military Grade: -40℃ ~ +85℃

Storage Temperature

-40℃


+125℃


Relative Humidity

5


95

%RH,Non-condensing

Cooling Method

Natural Cooling, Surface Heat Dissipation, or External Heatsink

Conversion Efficiency

Refer to Selection Table or Contact Customer Service

Enclosure Material

Aluminum Alloy

Power Supply Weight (Typical)

100g

Note 1

Note 1: Ripple noise is tested with a 20MHz bandwidth and parallel wiring;

Note 2: The leakage current for AC voltage testing is 5mA, and for DC voltage testing is 0.5mA;

Note 3: If it meets the relevant industry EMI standards, it is necessary to add the recommended external circuits or filters.

Ripple Test Method                                                                                

                                                                                                                        Load Power Routing 





                              Input 

                                                                 Power Module                                            Load 

                             (input) 






                                                                     Sampling Twisted Pair  


                                                                                                                                                                             Remove the probe cap 

                                                                                                                                                                              and ground wire from the probe



Application Circuit



                                                   Single Output                                                                  Dual Output Common Ground








                                                        Figure 1                                                                                         Figure 2




               Dual Output Isolated



 

                                                                                                    Figure 3

Output Voltage

C1

TVS

C2、C4

C3、C5

F1(A)

5Vdc

100μF

SMBJ7.0A

1μF

220μF

Maximum Input Current × 2

9Vdc

SMBJ12A

220μF

12/15Vdc

SMBJ20A

47μF

24Vdc

SMBJ30A

22μF

48Vdc

SMBJ64A

10μF

(Basic Application Table)

Recommended EMC Circuit



                                                                                                                                                          Figure 4






EMC Solution — Recommended Circuit (2)





Figure 5

Input Voltage

C1

C2、C6、C7、C8

C3、C4

C5

L1

L2、L3

Rv1

F1

Vin:24V

330μF/50V

1μF/50V

1nF/2KV

100μF

4.7μH

6-20mH

14D560K

Maximum Input Current × 2

Vin:48V

330μF/100V

1μF/100V

14D101K

Vin:110V

100μF/250V

1μF/250V

14D181K

1.Note: Part ① of Figure 4 and Figure 5 is used for EMS testing; Part ② is used for EMI filtering, and can be selected according to needs;

2.The pressure resistance of D1 is 2 times the maximum input voltage and the current is 3 times the maximum input current. The voltage resistance of the input TVS transient voltage suppression diode is greater than the highest input voltage.

3.For the output TVS, please refer to the basic application table.

Notice

1.It is generally recommended that the long-term operating power does not exceed 60–80% of the rated power to ensure better service life. Good ventilation is preferred; in poorly ventilated or enclosed environments, a larger power derating margin is required. Terminal-type power supplies should be mounted tightly against the metal casing of the equipment to maximize heat dissipation. Pin-type power supplies require effective ventilation for cooling. 

2.Please consider all factors and leave sufficient margin when selecting the power supply.

3.Please inform our customer service of the type of load or equipment connected to the power supply. If the load is inductive or capacitive, please specify clearly, as maximum current must be considered during power selection.

4.The application circuit is for reference only. Customers should make appropriate adjustments and verification based on their actual usage conditions.

5.Due to the specific nature of power supply products, it is recommended to purchase a few units for trial use before full deployment. Thoroughly test whether the power supply meets your requirements. For bulk orders, pricing is negotiable. As we are a self-developed manufacturer, we can offer discounts.

6.For terminal-type power supplies, the adapter base plate is not included by default. Customers requiring the base plate may specify this in their inquiry.Some power supply models do not feature input reverse polarity protection. Please ensure correct wiring during use, clearly identify the positive and negative terminals, and test with a multimeter first. Safety comes first.

7.It is normal for the power supply to generate heat during operation. Under standard conditions, a temperature rise of 20–30°C is perfectly normal. Do not judge the temperature by touch. The casing may become hot during operation and contact could cause burns.

8.Military-grade power supply lead time: 3–7 working days. For specific delivery time, please inquire with your parameters and order quantity.For military-grade power supplies, if customization is required, please confirm the specifications in advance.

9.If the load is inductive or capacitive, please confirm the maximum current.

Supplier Information

Company:eriksen

Email:halocore@ttbridge.com

Tel:13460222030

Recommended products

Military-Grade Wide Temperature AC-DC Power Module 30W-300W – 220VAC to 5V/9V/12V/15V/24V/28V for Industrial Systems

Military-grade isolated AC-DC power module with wide operating temperature range (-40℃ to +85℃), 30W to 300W, converting 220VAC to single regulated output.

collect:0

High Reliability Military-Grade Rugged DC-DC Power Module for Industrial & Railway Systems

Military-grade rugged isolated DC-DC power module with wide input range, 20W to 75W, and single regulated output for demanding applications.

collect:0

Military Grade Isolated DC DC Converter 50W 100W 150W Wide Input 12-110V to 5V 12V 24V Industrial Power Module

Isolated DC-DC power module with wide input voltage, ideal for industrial and communication applications.

collect:0